Cooling Only VRF System

(Design, Supply, Installation, Commissioning, Service & AMC for Cooling Only VRF / VRV Systems)

Design, Supply, Installation, Commissioning, Service & AMC for Cooling Only VRF / VRV Systems

In most Indian cities, buildings need cooling all year and rarely need heating. Paying for heating capability that will hardly ever be used makes little sense. A Cooling Only VRF System is designed for exactly this reality. It delivers efficient, zone-wise comfort cooling from compact outdoor units and flexible indoor units, without the added cost of heating components.

Compress India designs, supplies, installs, commissions, and maintains cooling only VRF and VRV systems for offices, retail spaces, restaurants, hotels, hospitals, and residences. From heat load calculation and refrigerant piping design to humidity control, BMS integration, and AMC, we deliver VRF cooling systems built for India's hot and humid climate.

Planning a new project or replacing multiple split ACs? Share your requirements with Compress India and get a VRF design and quotation.

Cooling Only VRF System

Compress India offers complete, end-to-end cooling only VRF solutions, managed by one experienced team:

  • Design: Cooling load calculation, zoning, outdoor and indoor unit selection, and VRF refrigerant piping design.
  • Supply: Cooling only VRF outdoor units, cassette, ducted, hi wall, and floor indoor units, fresh air units, and controllers from leading brands.
  • Installation: VRF copper piping, refnet joints, brazing, pressure testing, vacuuming, insulation, drain piping, ductwork, and communication wiring.
  • Commissioning: Refrigerant charging, addressing, test run, controls setup, and BMS integration.
  • Service & AMC: Preventive maintenance, error diagnostics, leak repairs, retrofits, and annual maintenance contracts.

What Is a Cooling Only VRF System?

A cooling only VRF system is a variable refrigerant flow air conditioning system that provides cooling but not heating. One outdoor unit, or a set of modular outdoor units, is connected through refrigerant piping to multiple indoor units in different rooms or zones.

Each indoor unit has its own controller, so every zone can be set to a different temperature and switched on or off independently. The outdoor unit's inverter compressors vary refrigerant flow to match the total cooling demand, delivering high efficiency and precise comfort.

Because it does not include heating components such as a reversing valve, a cooling only VRF is simpler and typically more economical than heat pump or heat recovery VRF. This makes it the natural choice for VRF comfort cooling in warm climates.

Why Cooling Only VRF Suits the Indian Climate

Most Indian cities, including Mumbai, Chennai, Hyderabad, Bengaluru, and Kolkata, need air conditioning for cooling through most of the year, with little or no heating demand.

  • Cooling-dominant weather: Heating is rarely needed, so heating components add cost without real value.
  • Hot summers: High ambient VRF units are built to keep cooling reliably in very high outdoor temperatures.
  • Humid coastal cities: Proper indoor unit selection and fresh air treatment manage humidity effectively.
  • Long operating hours: Inverter technology keeps running costs low across long cooling seasons.

For these reasons, a cooling only VRF is often the most cost-effective VRF air conditioning system for Indian commercial and residential projects.

How a Cooling Only VRF System Works

Inverter Outdoor Unit Varying Refrigerant Flow

The cooling only VRF outdoor unit contains inverter compressors that adjust speed based on the combined cooling demand from all indoor units, delivering only the capacity needed.

Refrigerant Piping & Branch Joints to Multiple Indoor Units

A two pipe cooling only VRF system runs a liquid line and a gas line from the outdoor unit, splitting through VRF Y joints or headers to each indoor unit.

Electronic Expansion Valves at Each Indoor Unit

Each indoor unit has an electronic expansion valve that controls refrigerant flow into its coil for accurate temperature control.

Zone-Wise Cooling Based on Demand

Every indoor unit cools its own zone as needed. Rooms that are unoccupied or already cool draw little or no refrigerant, saving energy and delivering true individual zone cooling.

Centralised & Individual Controls

Room controllers manage local comfort, while a VRF central controller allows building-wide monitoring and scheduling.

Main Components of a Cooling Only VRF System

Modular Outdoor Units

Outdoor units, also called VRF condensing units, come in modules that can be combined for higher capacities in large commercial VRF cooling systems.

Inverter Compressors

Inverter compressors deliver precise capacity control and high part-load efficiency.

Electronic Expansion Valves (EEV)

EEVs in each indoor unit fine-tune refrigerant flow for accurate zone temperatures.

Refnet Joints & Branch Headers

Refnet joints and headers split the VRF branch piping evenly to multiple indoor units.

Indoor Units

Cassette, ducted, hi wall, ceiling suspended, and floor standing indoor units suit every room type.

Controllers & BMS Gateways

Room controllers, central controllers, and BMS gateways provide local and central control.

Types of VRF Indoor Units

Hi Wall Indoor Units

VRF hi wall indoor units suit bedrooms, cabins, and small offices.

Cassette Indoor Units (4-Way, 2-Way, 1-Way, Round Flow)

VRF cassette indoor units fit in false ceilings. 4-way units suit open offices, while 2-way and 1-way units suit corridors and narrow rooms. Round flow units give 360-degree air distribution. A cooling only VRF cassette is one of the most popular choices for commercial spaces.

Ducted Indoor Units (Low, Medium & High Static)

VRF ducted indoor units and VRF ceiling concealed units are fully hidden, with only grilles visible. A cooling only VRF ducted unit is ideal for premium interiors.

Ceiling Suspended Indoor Units

These units hang below the ceiling and suit large rooms, restaurants, and spaces without a false ceiling.

Floor Standing & Console Units

These suit perimeter zones, glazed walls, and rooms without false ceilings.

Fresh Air Processing Units

These dedicated units cool and dehumidify 100% outdoor air before supplying it to the space. For larger airflow, a cooling only VRF with AHU, using a VRF AHU integration kit, is also possible.

Types of Cooling Only VRF Outdoor Units

Most VRF systems are air cooled VRF units that reject heat to outdoor air. Water cooled VRF options also exist for high-rise buildings where outdoor space is limited.

Top Discharge Modular Outdoor Units

Top discharge VRF outdoor units are the standard for commercial projects. They are combined in modules for large capacities and installed on terraces or service floors, making them ideal for a high capacity VRF system.

Side Discharge Mini VRF for Homes & Small Offices

Side discharge VRF outdoor units are compact and can be placed on balconies or ledges. A mini VRF cooling only system is ideal for villas, apartments, and small offices looking for a VRF AC for home or small commercial spaces.

High Ambient Outdoor Units

High ambient VRF cooling units are designed to operate reliably in extreme Indian summers, with some models rated for outdoor temperatures above 50°C.

Cooling Only VRF vs Heat Pump VRF vs Heat Recovery VRF

  • Function: Cooling only VRF provides cooling only. Heat pump VRF provides cooling or heating, with all zones in one mode. Heat recovery VRF provides simultaneous heating and cooling in different zones.
  • Components: Cooling only VRF has no reversing valve. A VRF heat pump system adds a reversing valve. Heat recovery VRF adds branch selector boxes and extra piping.
  • Piping: Cooling only and heat pump VRF use 2-pipe piping; heat recovery VRF usually uses 3-pipe piping or a BC controller.
  • Cost: Cooling only VRF is the most economical, heat pump VRF sits in the middle, and heat recovery VRF costs the most.
  • Best For: Cooling only VRF for hot climates across most of India; VRF heating and cooling systems for colder regions; VRF simultaneous heating and cooling for buildings with mixed loads.

When comparing cooling only VRF vs heat pump VRF, or cooling only VRF vs heat recovery VRF, Compress India recommends the right type based on your climate and building use.

Cooling Only VRF System Design & Sizing

Heat Load Calculation & Zoning

A detailed VRF cooling load calculation for every room forms the base of cooling only VRF system design. Rooms are grouped into zones based on usage, orientation, and operating hours.

Outdoor Unit Capacity (HP) Selection

Outdoor capacity is selected in HP based on the peak building load, applying a suitable VRF diversity factor.

Indoor-to-Outdoor Connection Ratio

The VRF combination ratio is kept within the manufacturer's allowed range, often between 50% and 130%, balancing cost, comfort, and efficiency.

Refrigerant Piping Length & Height Limits

VRF pipe sizing and routing must stay within the manufacturer's limits for total length, farthest unit, and height difference, to maintain capacity and oil return.

Refrigerant Concentration Limits & Safety

Room volumes are checked against the refrigerant charge to ensure safety in case of leaks.

Performance at High Ambient Temperatures

Outdoor unit capacity drops at very high outdoor temperatures. We select units and apply correction factors so the system delivers the required VRF cooling capacity on the hottest days.

Energy Efficiency of Cooling Only VRF Systems

Inverter Compressor Technology

Inverter compressors match output to demand, avoiding the energy waste of on/off cycling.

Part-Load Efficiency

Buildings run at part load most of the time. VRF part load efficiency is where the biggest savings come from.

EER & IEER Ratings

EER measures efficiency at full load, while IEER reflects efficiency across part-load conditions. An energy efficient cooling only VRF offers high ratings in both.

Refrigerants Used (R410A / R32)

Most systems use R410A, and R410A cooling only VRF is widely available. R32 VRF options are also emerging, offering lower global warming potential.

Humidity Control in Cooling Only VRF Systems

Dry Mode & Dehumidification

Indoor units offer dry mode, which runs the coil at lower airflow to remove more moisture during mild, humid weather.

Managing Humidity in Coastal Cities

In cities like Mumbai, correct indoor unit sizing, avoiding oversizing, and adequate coil temperatures help maintain comfortable indoor humidity.

Fresh Air Pre-Treatment

Humid outdoor air is the biggest source of indoor moisture. Pre-treating fresh air through a VRF treated fresh air unit or DOAS keeps indoor humidity under control.

VRF Controls & BMS Integration

Individual Room Controllers

Each room controller lets occupants set temperature, fan speed, and mode for true VRF zone control.

Centralised Controllers

Central controllers allow facility teams to monitor all indoor units, set schedules, and lock settings.

BMS Integration (BACnet / Modbus)

A cooling only VRF with BMS integration connects through VRF BACnet or VRF Modbus gateways.

Wi-Fi & Cloud-Based Monitoring

Remote platforms provide alerts, monitoring, and control from anywhere.

Power Apportioning for Tenant Billing

In multi-tenant buildings, energy use is apportioned to each tenant for accurate billing.

Scheduling & Setback Control

Schedules and setback temperatures prevent unnecessary cooling after hours and in unoccupied rooms.

Fresh Air Integration with Cooling Only VRF

VRF indoor units recirculate room air, so a VRF fresh air system must be planned separately for healthy indoor air.

Fresh Air Processing Units

These units cool and dehumidify outdoor air before supplying it to rooms.

Heat Recovery Ventilators (HRV / ERV)

HRVs and ERVs pre-cool incoming fresh air using exhaust air. ERVs also reduce the moisture brought in with fresh air, which is especially useful in humid climates.

Dedicated Outdoor Air Systems (DOAS)

A DOAS handles all fresh air separately, allowing the VRF system to focus on room cooling.

Benefits of Cooling Only VRF Systems

Lower Cost Than Heat Pump & Heat Recovery VRF

Without heating components, cooling only VRF offers lower equipment and installation costs.

Ideal for Hot & Humid Climates

Designed for cooling-dominant regions, it matches the needs of most Indian cities.

Individual Zone Temperature Control

Each room or zone has its own temperature setting, making it a true multi zone VRF cooling system.

High Energy Efficiency at Part Load

Inverter technology delivers excellent efficiency when the building is partly occupied.

No Chiller Plant, Pumps or Cooling Towers

Air cooled VRF needs no plant room, pumps, or cooling towers.

Compact Outdoor Units & Space Saving

Modular outdoor units take far less space than a central plant.

Flexible Design & Phased Installation

Zones and floors can be added in phases as the building is occupied.

Limitations of Cooling Only VRF Systems

No Heating Capability

Cooling only VRF cannot provide heating. For colder regions, heat pump or heat recovery VRF is required.

Refrigerant Piping Length Limits

Piping lengths and height differences must stay within manufacturer limits.

Refrigerant Leak Risk & Safety Considerations

Leak prevention, detection, and refrigerant concentration checks are important.

Higher Initial Cost Than Split ACs

VRF costs more upfront than individual split ACs, though it offers better efficiency, control, and aesthetics.

Fresh Air Needs Separate Provision

Fresh air must be planned through fresh air units, ERVs, or DOAS.

Requires Skilled Installation

Brazing, pressure testing, vacuuming, and charging must be done precisely by trained technicians.

Compress India plans and executes every cooling only VRF project to manage these limitations effectively.

Cooling Only VRF vs Chiller System

  • Scale: VRF suits small to large buildings; chiller VRF comparisons usually favour chillers for very large buildings and campuses.
  • Plant Space: VRF needs no chiller plant room, pumps, or cooling towers.
  • Zone Control: VRF offers built-in individual zone control; chiller systems need FCUs and AHUs with controls.
  • Efficiency: VRF is highly efficient at part load; large chiller plants can be very efficient at scale.
  • Best For: Cooling only VRF for offices, retail, hotels, and villas; chillers for malls, airports, and large campuses.

When comparing cooling only VRF vs chiller system, Compress India evaluates both for your building.

Cooling Only VRF vs Multiple Split ACs

  • Outdoor Units: VRF uses a few modular outdoor units for many rooms; split ACs need one outdoor unit per indoor unit.
  • Aesthetics: VRF keeps facades clean.
  • Efficiency: VRF offers higher part-load efficiency and central control.
  • Indoor Options: VRF offers cassette, ducted, and floor units on one system.
  • Cost: Split ACs cost less initially; VRF offers better long-term value for larger spaces.

When comparing cooling only VRF vs split AC, VRF becomes the better choice once a building has many rooms or needs central control.

Cooling Only VRF vs Ducted / Packaged AC

  • Zoning: VRF offers room-by-room control; ducted and packaged units usually control a large area as one zone.
  • Efficiency: VRF inverter technology is typically more efficient at part load.
  • Ductwork: VRF needs little or no ductwork.
  • Best For: VRF for multi-room buildings; packaged units for single large spaces like halls.

Where Cooling Only VRF Systems Are Used

Corporate Offices & IT Spaces

A cooling only VRF for offices provides cabin-wise and floor-wise control with tenant billing and BMS integration.

Retail Showrooms & Mall Tenant Spaces

A cooling only VRF for shopping mall tenants and showrooms offers flexible zoning and clean interiors.

Restaurants & Cafés

Multiple indoor units handle dining and private areas with different cooling loads.

Hotels in Coastal & Tropical Cities

A cooling only VRF for hotels delivers quiet, individually controlled cooling with central monitoring.

Hospitals & Clinics

VRF provides zone control for consultation rooms, wards, and offices, with fresh air planned separately.

Banks & Financial Offices

VRF delivers reliable, quiet cooling for customer areas, cabins, and server rooms.

Schools & Coaching Centres

Scheduled cooling for classrooms and offices keeps energy use in check.

Villas & Premium Apartments

A mini VRF gives homes concealed, room-wise cooling from one compact outdoor unit. It is also a practical cooling only VRF for high rise buildings where many split outdoor units are not allowed.

Top Cooling Only VRF Brands in India

Compress India supplies and installs cooling only VRF systems from leading brands, recommending the right option based on capacity, features, budget, and service support.

Daikin (VRV)

Daikin originated the VRV concept, and Daikin VRV systems are widely used in Indian commercial and residential projects.

Mitsubishi Electric

The Mitsubishi Electric VRF system range offers a wide choice of outdoor and indoor units for commercial buildings.

Hitachi

Hitachi VRF systems offer modular outdoor units for commercial applications.

Toshiba

Toshiba VRF systems are known for modular designs and efficient operation.

LG (Multi V)

The LG VRF system, sold as Multi V, offers solutions for commercial and residential use.

Samsung (DVM)

Samsung VRF AC systems under the DVM range offer modular outdoor units and flexible indoor options.

Blue Star

Blue Star VRF systems are offered by one of India's well-known HVAC brands.

Voltas

Voltas VRF systems are part of the brand's central air conditioning range.

Carrier

Carrier VRF systems are available for commercial cooling applications.

Cooling Only VRF Installation Guide

Cooling only VRF installation quality decides system life and efficiency. Compress India follows strict manufacturer and industry practices.

Outdoor Unit Placement & Clearances

Outdoor units are placed with proper service clearances, good airflow, and protection from hot air recirculation, which is critical in hot climates.

Refrigerant Pipe Sizing & Routing

Pipes are sized using manufacturer software and routed within length and height limits.

Brazing with Nitrogen Purging

All joints are brazed with nitrogen flowing through the pipe to prevent internal oxidation.

Refnet Joint Installation

Refnet joints are installed in the correct orientation for even refrigerant and oil distribution.

Nitrogen Pressure Testing

The piping is pressure tested with nitrogen and held to confirm there are no leaks.

Vacuuming & Dehydration

The system is evacuated to a deep vacuum to remove air and moisture.

Additional Refrigerant Charge Calculation

Additional refrigerant is calculated from actual pipe lengths and charged accurately by weight.

Pipe Insulation & Drain Piping

Pipes are insulated to prevent condensation, and indoor unit drains are laid with proper slope.

Communication Wiring & Addressing

Communication wiring is installed correctly and every indoor unit is addressed.

Test Run & Commissioning

The system is test run, operating data is recorded, and controls are verified before handover.

Cooling Only VRF Service, Maintenance & AMC

Regular maintenance protects efficiency, reliability, and compressor life. Compress India offers preventive maintenance and AMC plans for cooling only VRF systems of all major brands.

Indoor Unit Filter & Coil Cleaning

Filters are cleaned regularly and coils are cleaned periodically to maintain airflow and cooling.

Outdoor Unit Coil Cleaning

Outdoor coils are cleaned to maintain heat rejection, which is especially important in dusty and coastal areas.

Refrigerant Leak Checks

Joints and connections are checked for leaks to maintain refrigerant charge and efficiency.

Error Code Diagnostics

Error codes are read and analysed to identify faults quickly.

Compressor & PCB Health Checks

Compressor current, pressures, and PCB condition are checked to catch problems early.

Comprehensive vs Non-Comprehensive AMC

  • Comprehensive AMC: Covers scheduled maintenance plus specified spare parts, with predictable annual costs.
  • Non-Comprehensive AMC: Covers scheduled maintenance and service visits, with spare parts charged separately.

Common Cooling Only VRF Problems & Solutions

Some Indoor Units Not Cooling

Causes: EEV faults, low refrigerant, piping issues, or addressing errors.

Solution: Check EEVs, charge, piping, and addressing, and correct faults.

Refrigerant Leakage

Causes: poor brazing, vibration, or damaged pipes.

Solution: Locate and repair leaks, pressure test, vacuum, and recharge.

Communication Errors

Causes: loose or damaged wiring, or addressing errors.

Solution: Inspect wiring and re-address units.

Error Codes on Controllers

Causes: sensor faults, PCB issues, or operating limits being exceeded.

Solution: Diagnose using the error code and replace faulty parts.

Outdoor Unit Tripping in High Ambient

Causes: dirty coils, hot air recirculation, or poor ventilation.

Solution: Clean coils, improve clearances, and prevent recirculation.

Water Leakage from Indoor Units

Causes: blocked drains, drain pump failure, or poor slope.

Solution: Clean drains, repair pumps, and correct slopes.

High Humidity in Occupied Spaces

Causes: oversized indoor units, untreated fresh air, or high coil temperatures.

Solution: Review sizing, add fresh air pre-treatment, and adjust settings.

Cooling Only VRF Retrofit & Upgrades

Replacing Multiple Split ACs with VRF

Buildings with many split ACs can switch to a cooling only VRF system, reducing outdoor units, improving aesthetics, and lowering energy use.

Replacing Old R22 VRF Systems

Old R22 systems can be replaced with modern, efficient VRF systems. In some cases, existing piping can be reused after inspection and cleaning.

Adding Indoor Units to an Existing System

Additional indoor units can be connected within the outdoor unit's connection ratio and piping limits.

Controls & BMS Upgrades

Upgraded controllers and BMS gateways improve monitoring, scheduling, and energy management.

Cooling Only VRF System Price in India

The cooling only VRF price in India depends on outdoor capacity, brand, indoor unit types, piping length, controls, and installation scope. Compress India provides a detailed quotation after understanding your project.

VRF Price per HP

VRF systems are commonly priced per HP of outdoor capacity. Cooling only systems are generally more economical per HP than heat pump or heat recovery systems.

Indoor Unit Cost

Indoor unit cost depends on type and capacity. Cassette and ducted units generally cost more than hi wall units.

Piping, Installation & Controls Cost

Refrigerant piping, refnet joints, insulation, drain piping, ductwork, controllers, and BMS integration form a significant part of the total cost.

Factors Affecting Total Project Cost

Building size, number of zones, indoor unit mix, piping lengths, fresh air system, controls, and site conditions all affect the final VRF AC system price.

Share your floor plans with Compress India to receive an accurate cooling only VRF quotation.

Cooling Only VRF Design, Installation & Service in Mumbai, Navi Mumbai & Thane

As an experienced cooling only VRF supplier and installer, Compress India provides design, supply, installation, commissioning, service, and AMC across Mumbai, Navi Mumbai, and Thane. Mumbai's cooling-dominant, humid, and coastal climate makes cooling only VRF an excellent fit. We select high ambient and corrosion-protected outdoor units and design fresh air treatment to keep humidity under control.

Whether you are fitting out an office, a showroom, a restaurant, or a premium residence, our local team offers fast site visits and dependable support.

Why Choose Compress India for Cooling Only VRF Systems?

Heat Load & Zoning Design

We carry out detailed heat load calculations and zoning to size every outdoor and indoor unit correctly.

Multi-Brand VRF Supply

We work with leading VRF brands and recommend the best-fit system for your budget and requirements.

Refrigerant Piping Expertise

Our trained team follows nitrogen brazing, pressure testing, and vacuuming procedures for leak-free installations.

Ductwork & Fresh Air Integration

We design and install ductwork for ducted units along with fresh air and humidity control systems.

Controls & BMS Integration

We integrate VRF systems with central controllers and BMS for monitoring, scheduling, and tenant billing.

Testing & Commissioning

Every system is tested, charged, addressed, and commissioned as per manufacturer standards.

AMC & Retrofit Support

We provide preventive maintenance, AMC plans, and retrofit upgrades for VRF systems of all major brands.

Get a Cooling Only VRF Solution from Compress India

Looking for efficient, flexible, room-by-room cooling built for Indian conditions? Compress India delivers complete cooling only VRF systems for commercial buildings and residences, from design and supply to installation, commissioning, and long-term service.

Connect with Our HVAC Team

Share your floor plans, room list, or details of your existing system with our team. Call us or fill in the enquiry form to schedule a site visit and receive a detailed VRF design and quotation.

Along with cooling only VRF, Compress India offers heat pump VRF, heat recovery VRF, chillers, AHUs, FCUs, ductwork, fresh air systems, and complete central air conditioning solutions.

Heat Pump VRF System

Heat Pump VRF System

Learn More
Heat Recovery VRF System

Heat Recovery VRF System

Learn More
High-Rise VRF System

High-Rise VRF System

Learn More
Air Cooled VRF System

Air Cooled VRF System

Learn More
Water Cooled VRF System

Water Cooled VRF System

Learn More

Frequently Asked Questions

Q1: What is a cooling only VRF system?

A cooling only VRF system is a variable refrigerant flow system that provides cooling only. One outdoor unit serves multiple indoor units, with individual temperature control in each zone.

Q2: How does a cooling only VRF system work?

An inverter outdoor unit varies refrigerant flow to indoor units based on demand, and electronic expansion valves control cooling in each zone.

Q3: What is the difference between cooling only VRF and heat pump VRF?

Cooling only VRF provides only cooling. Heat pump VRF can provide either cooling or heating by reversing the refrigerant cycle.

Q4: Is a cooling only VRF system suitable for the Indian climate?

Yes. Most Indian cities are cooling-dominant, making cooling only VRF a practical and cost-effective choice.

Q5: Is a cooling only VRF cheaper than a heat pump VRF?

Generally yes. Without heating components, cooling only VRF typically has a lower equipment and installation cost.

Q6: How many indoor units can be connected to one cooling only VRF outdoor unit?

It depends on the brand and outdoor capacity. Large modular systems can typically connect up to around 64 indoor units within the allowed connection ratio.

Q7: Can a cooling only VRF work in high ambient temperatures?

Yes. High ambient models are designed to operate reliably in very hot conditions, with some rated for outdoor temperatures above 50°C.

Q8: Can a cooling only VRF system control humidity?

Yes, with correct unit sizing, dry mode operation, and pre-treatment of fresh air through a fresh air unit or DOAS.

Q9: Is a VRF system better than multiple split ACs?

For buildings with many rooms, VRF offers better efficiency, central control, cleaner facades, and more indoor unit options than multiple split ACs.

Q10: How often should a cooling only VRF system be serviced?

Indoor filters should be cleaned every two to four weeks, with full preventive maintenance done quarterly or as per usage.

Q11: What is the price of a cooling only VRF system in India per HP?

The price per HP depends on the brand, efficiency, indoor unit mix, piping, and installation scope. Contact Compress India with your floor plans for an accurate quotation.

Q12: Does Compress India design and install cooling only VRF systems in Mumbai?

Yes. Compress India designs, supplies, installs, and services cooling only VRF systems across Mumbai, Navi Mumbai, and Thane, along with AMC and retrofit support.