Basement Exhaust Systems

(Design, Supply, Installation, Testing, Commissioning & AMC for Basement Exhaust & Mechanical Ventilation Systems)

Design, Supply, Installation, Testing, Commissioning & AMC for Basement Exhaust & Mechanical Ventilation Systems

Compress India provides complete Basement Exhaust Systems for underground parking areas, multi-level basements, commercial buildings, residential towers, shopping malls, hospitals, hotels, IT parks, data centres, industrial facilities and other enclosed basement spaces.

An enclosed basement requires carefully engineered mechanical ventilation to remove vehicle exhaust fumes, control carbon monoxide and nitrogen dioxide, introduce fresh air, prevent stagnant pollutant zones and support smoke extraction during fire emergencies.

Our scope covers Basement Exhaust System Design, supply, installation, testing, commissioning, retrofit and AMC, including exhaust fans, fresh air fans, jet fans, ductwork, shafts, louvers, CO and NO₂ sensors, VFDs, fire-mode controls and BMS integration.

Compress India develops each Basement Ventilation System according to basement area and volume, parking capacity, traffic movement, required air changes, pollutant generation, fire strategy, duct resistance, shaft availability and building configuration.

Whether your project needs a conventional ducted exhaust system, a Car Park Jet Fan System, demand-controlled ventilation or a combined normal and smoke exhaust solution, our HVAC team can provide an engineered approach.

Basement Exhaust Systems

Compress India provides end-to-end services for Basement Mechanical Ventilation and underground parking exhaust systems.

Our services can include airflow calculations, ACH calculations, ventilation zoning, exhaust fan sizing, fresh air sizing, duct and shaft design, jet fan layout, CO and NO₂ monitoring, VFD selection, smoke exhaust design, CFD support, fire alarm integration, controls, BMS integration, installation, testing and commissioning.

For existing basements, we also troubleshoot high CO levels, weak exhaust, dead-air zones, poor jet-fan performance, excessive negative pressure, high energy consumption, fan noise and inadequate smoke-exhaust operation.

The objective is to create a controlled airflow path throughout the basement rather than simply installing large exhaust fans.

Share your basement layout, parking capacity, number of levels and project requirements with Compress India for a project-specific assessment and quotation.

What Is a Basement Exhaust System?

A Basement Exhaust System is a mechanical ventilation system designed to remove polluted, stale or smoke-contaminated air from enclosed basement spaces and replace it with fresh outdoor air.

In parking areas, the system primarily controls contaminants produced by vehicles, including carbon monoxide and nitrogen oxides.

A typical Basement Parking Exhaust System can include exhaust fans, supply fans, ducts, shafts, louvers, jet fans, CO sensors, NO₂ sensors, VFDs, dampers and controls.

During normal operation, the system may run at reduced capacity depending on pollutant levels.

During a fire emergency, selected fans, dampers and jet fans can switch to a predefined smoke-control sequence according to the approved fire strategy.

Why Basement Exhaust Ventilation Is Important

Removing Vehicle Exhaust Fumes

Cars and other vehicles release combustion products while starting, idling and travelling through parking areas.

Basement Exhaust Ventilation removes these pollutants before they accumulate throughout the enclosed space.

Controlling Carbon Monoxide (CO)

Carbon monoxide can build up in poorly ventilated parking areas.

A Basement CO Exhaust System uses ventilation and CO monitoring to maintain appropriate air quality during normal basement operation.

Controlling Nitrogen Oxides (NOx)

Vehicle exhaust can also contain nitrogen oxides, including nitrogen dioxide.

Projects may therefore use NO₂ monitoring together with CO sensors to improve contaminant control.

Removing Heat & Stale Air

Vehicles, lighting, electrical services and surrounding building spaces contribute heat.

Mechanical ventilation helps remove warm, stagnant air and improve basement conditions.

Maintaining Safe Indoor Air Quality

Effective ventilation dilutes pollutants and continuously replaces contaminated air with cleaner outdoor air.

Preventing Pollutant Build-Up in Enclosed Basements

Deep and multi-level basements have limited natural ventilation.

Without mechanical air movement, pollutants can accumulate in corners and areas shielded by columns, walls or parked vehicles.

Controlling Smoke During Fire Emergencies

A Basement Smoke Exhaust System can be configured to remove smoke during a fire and support the building's approved smoke-control strategy.

Maintaining Safe Conditions for Occupants & Maintenance Staff

Drivers, security personnel and maintenance staff regularly enter basement areas.

Effective air movement improves conditions for everyone using or servicing the space.

Meeting Building & Fire Safety Requirements

Basement exhaust, smoke control and fire-mode operation should be coordinated with applicable building, mechanical ventilation and fire-safety requirements.

How a Basement Exhaust System Works

1. Fresh Air Enters the Basement Through Louvers, Shafts or Supply Fans

Outdoor air enters through natural openings, dedicated fresh-air shafts or mechanical supply fans.

2. Supply Air Moves Through the Basement

Fresh air is distributed through ducts, grilles or open airflow paths.

In jet-fan systems, impulse fans help move air across large parking areas.

3. Vehicle Fumes & Contaminated Air Are Diluted

Incoming fresh air dilutes pollutants produced by vehicle movement.

4. Exhaust Points Collect Polluted Air

Exhaust grilles, ducts or shafts are positioned to capture contaminated air and encourage movement throughout the basement.

5. Exhaust Fans Remove Contaminated Air

A Basement Exhaust Fan creates the pressure required to move contaminated air toward the outdoor discharge.

6. Exhaust Air Is Discharged Safely Outdoors

Exhaust outlets should be positioned to reduce the possibility of fumes returning through fresh-air intakes or entering occupied areas.

7. CO Sensors Modulate Ventilation During Normal Operation

CO sensors can reduce fan operation during low vehicle activity and increase ventilation as pollutant concentration rises.

8. Fire Alarm Signal Switches the System to Smoke Exhaust Mode

During fire mode, the control sequence may change fan speeds, operate smoke exhaust fans, reposition dampers and run jet fans according to the approved fire strategy.

Main Components of a Basement Exhaust System

Basement Exhaust Fans

Exhaust fans remove polluted air from the basement and discharge it outdoors.

Fresh Air Supply Fans

Supply fans introduce outdoor air when natural intake is inadequate.

Jet Fans / Impulse Fans

Jet fans create directional air movement without requiring extensive low-level ductwork across the complete parking area.

Exhaust Air Ductwork

Ductwork carries contaminated air from basement extraction points to shafts or fans.

Fresh Air Ductwork

Fresh air ducts distribute incoming outdoor air throughout enclosed basement areas.

Exhaust Grilles

Exhaust grilles form terminal points through which polluted air enters the duct system.

Fresh Air Grilles

Fresh-air grilles distribute replacement air into the basement.

Intake & Discharge Louvers

Louvers provide weather-protected external openings for fresh-air intake and exhaust discharge.

Ventilation Shafts

Vertical shafts carry supply or exhaust airflow between basement levels and outdoor discharge points.

Smoke Exhaust Shafts

Dedicated smoke shafts may be provided where required by the fire and smoke-control design.

Motorised Dampers

Motorised dampers control airflow paths during normal operation and fire mode.

Fire & Smoke Dampers

Fire and smoke dampers may be required where ducts cross fire-rated boundaries, subject to the approved fire strategy.

CO Sensors

CO sensors monitor carbon monoxide concentration and can automatically control ventilation demand.

NO2 Sensors

NO₂ sensors provide additional monitoring of vehicle-related pollutants.

Temperature Sensors

Temperature sensors can support plant monitoring, smoke-control operation or other project-specific sequences.

Variable Frequency Drives (VFDs)

VFDs allow fan speed to change according to ventilation demand.

MCC & Control Panels

Control panels operate fans, dampers, sensors, alarms and associated ventilation equipment.

Fire Alarm & BMS Integration

Integration allows the system to respond automatically to fire signals and enables monitoring from the building management system.

Basement Exhaust Airflow & ACH Calculation

Basement Floor Area & Volume

Ventilation calculations begin with the usable basement area, clear height and total enclosed volume.

Normal Ventilation Air Change Requirement

The required normal-operation airflow can be assessed through applicable air-change and contaminant-control criteria.

Fire & Smoke Exhaust Air Change Requirement

Fire-mode exhaust may require a different airflow than everyday pollutant ventilation.

Vehicle Movement & Occupancy

Parking capacity, traffic frequency and vehicle movement affect pollutant generation.

Carbon Monoxide Generation

Expected CO levels and vehicle activity influence the ventilation strategy.

Nitrogen Dioxide Generation

Projects with significant diesel-vehicle use may require greater attention to NO₂ monitoring and control.

Fresh Air Requirement

Fresh-air quantity must support dilution and replacement of exhausted air.

Exhaust Air Quantity

The final Basement Exhaust CFM or equivalent airflow is determined according to the applicable design basis.

Shaft & Duct Pressure Loss

Pressure losses through ducts, shafts, grilles, dampers and louvers are included in the system calculation.

Fan Static Pressure Calculation

Fans must provide the required airflow at the calculated external static pressure.

Multiple Basement Level Calculations

Each basement level should be evaluated according to its area, traffic and ventilation arrangement.

Ventilation Zoning & Diversity

Large basements can be divided into zones to improve control and reduce unnecessary fan operation.

Normal Basement Ventilation Design

Day-to-Day Vehicle Fume Removal

Normal operation is designed to dilute and remove pollutants generated by everyday vehicle activity.

Fresh Air Supply Requirement

Adequate replacement air should be introduced to support exhaust operation.

Exhaust Air Distribution

Extraction points should be distributed to pull polluted air across the basement.

CO-Based Ventilation Control

CO sensors can stage or modulate ventilation according to actual contaminant levels.

NO2-Based Ventilation Control

NO₂ monitoring can be integrated where diesel emissions are a significant consideration.

Maintaining Air Movement Across the Basement

Air movement should reach parking bays, circulation lanes, ramps and peripheral spaces.

Avoiding Pollutant Dead Zones

Columns, walls and service rooms can create stagnant locations.

Air distribution should be developed to reduce these dead zones.

Preventing Supply-to-Exhaust Short-Circuiting

Fresh air should travel through occupied basement zones rather than immediately leaving through the nearest exhaust opening.

Energy-Efficient Part-Load Operation

VFD control and sensor-based staging can reduce fan energy during periods of low traffic.

Basement Smoke Exhaust Design

Smoke Removal During Fire Conditions

A Basement Smoke Control System is intended to manage smoke movement according to the approved fire-safety strategy.

Fire Mode Air Change Requirement

Fire-mode airflow should be calculated separately from normal ventilation where the project requires different operating criteria.

Smoke Exhaust Fan Capacity

Smoke exhaust fans are selected according to the required fire-mode airflow and system pressure.

Smoke Exhaust Shaft Sizing

Smoke shafts must accommodate the required airflow while maintaining acceptable velocity and pressure loss.

Smoke Exhaust Duct Sizing

Smoke exhaust ductwork is designed for the required fire-mode duty and routing.

Make-Up Air During Smoke Exhaust

Replacement air is necessary so that smoke exhaust fans can operate effectively without producing excessive negative pressure.

Smoke Zone & Compartment Coordination

Ventilation zones should align with the approved fire compartment and smoke-control strategy.

Fire Alarm System Integration

Fire-mode operation can be initiated automatically through the building fire alarm system.

Automatic Changeover to Fire Mode

Normal ventilation controls may be overridden so that fans and dampers operate according to the fire sequence.

Emergency Manual Override

Manual control may be provided at the designated fire command location where required by the project.

Fire-Rated Fan Requirements

Fans serving smoke-exhaust duty should meet the temperature and duration performance required by the approved design.

Fire Survival of Electrical Power & Controls

Power supplies, cables and controls serving life-safety ventilation should be coordinated with the project's fire-survival requirements.

Basement Fresh Air & Make-Up Air Design

Fresh Air Quantity Calculation

Fresh-air volume is determined in coordination with exhaust requirements.

Natural Fresh Air Openings

Basements with suitable external exposure may use natural openings for part of the replacement-air requirement.

Mechanical Fresh Air Supply

Where natural airflow is insufficient, mechanical supply fans can provide controlled fresh air.

Fresh Air Shaft Sizing

Supply shafts should be large enough to carry the required airflow without excessive pressure drop.

Fresh Air Louver Sizing

Louver sizing should consider effective free area, air velocity and resistance.

Make-Up Air for Normal Exhaust

Normal exhaust operation requires sufficient incoming air to replace air being removed.

Make-Up Air During Fire Mode

Fire-mode exhaust can require substantially different replacement-air arrangements.

Fresh Air Distribution Across the Basement

Fresh air should be distributed so that it sweeps through the basement rather than remaining concentrated near the intake.

Avoiding Short-Circuit Airflow

Intakes and exhaust points should be positioned to encourage useful air movement.

Preventing Excessive Basement Negative Pressure

Insufficient make-up air can produce excessive negative pressure, door-opening problems and reduced exhaust performance.

Carbon Monoxide (CO) Control in Basements

Sources of Carbon Monoxide in Basement Parking

CO is produced by combustion engines, particularly during starting, idling and low-speed movement.

CO Sensor Locations

Sensors should be distributed in representative parking and traffic areas rather than concentrated in one location.

CO Monitoring Zones

Large basements can be divided into monitoring zones for more responsive ventilation control.

Fan Start-Stop Based on CO Levels

Fans can automatically start or stage as measured CO concentration increases.

VFD Modulation Based on CO Concentration

A CO Sensor Controlled Ventilation system can vary fan speed according to real-time demand.

High CO Alarm

High pollutant concentration can trigger an alarm to the BMS or facility team.

Integration with BMS

CO readings, fan status and alarms can be monitored centrally.

Sensor Calibration & Maintenance

Sensors require periodic calibration and functional checks to maintain accurate control.

Maintaining Safe Contaminant Levels

Sensor-controlled ventilation should maintain pollutant concentrations within the applicable project limits.

NO2 & Vehicle Emission Control

Nitrogen Dioxide from Vehicle Exhaust

NO₂ is another important pollutant associated with combustion-engine emissions.

Diesel Vehicle Emissions

Diesel vehicles can contribute significantly to nitrogen oxide concentrations in enclosed parking areas.

NO2 Sensor Placement

Sensors should be positioned in locations representative of expected pollutant exposure.

Combined CO & NO2 Monitoring

Combined monitoring provides more comprehensive vehicle-emission control.

Ventilation Fan Control Based on Air Quality

The ventilation system can increase airflow when either monitored pollutant reaches the configured control threshold.

High Pollutant Alarm

High readings can generate alarms for facility operators.

Ventilation Requirements for High-Traffic Basements

Parking facilities with frequent vehicle movement may require greater airflow or more responsive demand control.

Basement Air Distribution Design

Fresh Air Entry Locations

Fresh-air locations influence the overall airflow path.

Exhaust Point Locations

Exhaust points should encourage contaminated air to travel away from occupied access zones.

High-Level Exhaust

High-level extraction can support removal of warmer air and specific contaminants depending on the design.

Low-Level Exhaust

Low-level extraction may be incorporated where required by pollutant-distribution or project criteria.

Longitudinal Air Movement

Air can be directed along parking lanes toward extraction shafts.

Cross-Basement Air Movement

Cross-flow arrangements can be used where suitable to sweep wide parking areas.

Eliminating Dead Air Zones

Fan and grille locations should address spaces behind columns and other obstructions.

Avoiding Airflow Short-Circuiting

Supply and exhaust should be separated sufficiently to prevent ineffective local circulation.

Ramp & Driveway Airflow

Ramps influence pressure and natural airflow and should be considered as part of the complete basement system.

Air Movement Around Columns & Obstructions

Structural columns, beams, parked cars and services can interfere with airflow and should be considered during layout development.

Jet Fan & Impulse Ventilation Design

Jet Fan Coverage Planning

A Basement Jet Fan Ventilation system uses impulse fans to move air across defined sections of the parking area.

Jet Fan Thrust Selection

Fan thrust is selected according to the required air movement and basement geometry.

Jet Fan Location & Orientation

Jet fans should be positioned and aimed toward intended airflow paths.

Creating Defined Airflow Paths

Jet fans guide air from fresh-air zones toward exhaust shafts or extraction points.

Moving Polluted Air Towards Exhaust Shafts

Directional thrust reduces reliance on extensive horizontal ductwork.

Eliminating Stagnant Air Zones

Additional fans can target regions where normal air movement is weak.

Jet Fan Spacing

Spacing depends on thrust, ceiling configuration and obstructions.

Ceiling Height & Beam Coordination

Structural beams can block jet-fan discharge and reduce effective throw.

Avoiding Structural Obstructions

Fan orientation should account for columns, signs, pipes, cable trays and other services.

Normal Ventilation Operation

Jet fans can run at low or staged capacity to assist everyday contaminant removal.

Smoke Control Operation

During fire mode, the operating sequence may change to support the approved smoke-management strategy.

CFD-Based Jet Fan Validation

Complex systems may be evaluated using CFD to validate airflow and smoke movement.

CFD Analysis for Basement Ventilation

Airflow Pattern Simulation

CFD can visualise how air travels through the basement.

CO Concentration Analysis

Modelling can identify areas where vehicle pollutants may accumulate.

Smoke Movement Simulation

Fire scenarios can be modelled to assess smoke movement through the basement.

Jet Fan Performance Analysis

Simulation helps evaluate whether jet-fan placement and thrust produce the intended airflow.

Dead Zone Identification

CFD can highlight low-velocity regions requiring ventilation improvements.

Supply & Exhaust Location Optimisation

Intake and exhaust positions can be adjusted to improve overall circulation.

Smoke Clearance Analysis

The model can support assessment of smoke-removal performance according to the design scenario.

Visibility Analysis During Fire

Where required, modelling can assess visibility conditions under defined fire scenarios.

Temperature & Smoke Spread Assessment

CFD can help evaluate hot smoke movement and temperature distribution.

Final Ventilation Design Validation

For complex projects, CFD provides an additional design-validation tool before final execution.

Basement Exhaust Fan Selection

Required Exhaust Airflow

Fan capacity should match the calculated normal or smoke-exhaust airflow.

External Static Pressure

Pressure resistance from ducts, shafts, grilles, dampers and louvers must be calculated.

Fan Duty Point Selection

The fan should deliver the required airflow at the actual system resistance.

Normal Ventilation Duty

Normal-operation fans can be selected for everyday contaminant-control requirements.

Fire & Smoke Exhaust Duty

Smoke-exhaust fans require selection according to the fire-mode operating condition.

Fire-Rated Fan Selection

Where required, fans should carry the appropriate high-temperature performance classification specified by the design.

Axial Fan Selection

A Basement Axial Exhaust Fan can provide high airflow where system resistance suits axial-fan operation.

Centrifugal Fan Selection

A Basement Centrifugal Exhaust Fan may be more suitable where higher pressure is required.

Fan Efficiency

Efficient selection reduces electrical consumption over long operating hours.

Motor Efficiency

High-efficiency motors can further reduce fan energy demand.

Noise & Vibration Control

Fan speed, mounting, vibration isolation and duct configuration influence noise.

VFD Compatibility

Fans and motors intended for variable-speed operation should be suitable for VFD control.

Standby & Redundancy Requirements

Critical or life-safety applications may require standby equipment according to project requirements.

Basement Exhaust Ductwork Design

Exhaust Duct Sizing

Duct dimensions are selected according to airflow, velocity, available space and pressure loss.

Fresh Air Duct Sizing

Fresh-air ductwork should deliver replacement air with acceptable resistance and noise.

Air Velocity Selection

Velocity affects duct size, pressure loss, noise and ceiling-space requirements.

Duct Static Pressure Loss

Losses through straight sections, bends, transitions and fittings are included in fan calculations.

Low-Level Exhaust Ducting

Low-level ducts may be incorporated where required by the ventilation strategy.

High-Level Exhaust Ducting

High-level ducts are commonly used to collect air above parking zones or service areas.

Smoke Exhaust Ductwork

Smoke ductwork should follow the approved fire and smoke-control design.

Fire-Rated Duct Requirements

Where fire-rated construction is required, materials and installation should comply with the approved project specification.

Duct Leakage Control

Properly fabricated and sealed ductwork helps maintain intended airflow.

Access Panels

Access should be provided where internal inspection or maintenance may be necessary.

Coordination with Structural Beams

Basement services must be coordinated carefully around beams and other structural elements.

Maintaining Vehicle Clearance Height

Duct routing should preserve required parking and vehicle circulation clearances.

Basement Ventilation Shaft Design

Fresh Air Shaft Sizing

Fresh-air shafts should accommodate the required volume without excessive pressure loss.

Exhaust Air Shaft Sizing

Exhaust shafts carry contaminated air from basement levels toward the outdoor discharge.

Smoke Exhaust Shaft Sizing

Smoke shafts are sized according to the fire-mode airflow requirement.

Shaft Air Velocity

Appropriate velocity balances shaft size against pressure and acoustic performance.

Shaft Pressure Drop

Long or narrow shafts can create significant resistance.

Multi-Level Basement Shaft Coordination

Shaft allocation should account for airflow from every connected level.

Separate Basement Ventilation Zones

Large projects may benefit from independent shafts or controlled zones.

Fire-Rated Shaft Construction

Smoke or ventilation shafts may require fire-rated construction according to the project strategy.

Shaft Access & Maintenance

Inspection and service access should be considered during planning.

Intake & Discharge Separation

Fresh-air shaft openings and exhaust outlets should be positioned to reduce recirculation.

Intake & Exhaust Louver Design

Louver Free Area Calculation

Actual free area should be used when evaluating airflow capability.

Face Velocity

Excessive louver velocity increases pressure drop and may increase rain-entry risk.

Pressure Drop

Louver resistance contributes to total system static pressure.

Weather Protection

External openings should resist normal weather exposure.

Bird & Insect Screens

Screens can provide protection but also add airflow resistance.

Rainwater Ingress Prevention

Proper louver selection and external detailing reduce water entry.

Acoustic Louver Requirements

Acoustic louvers can be used where fan or airflow noise requires attenuation.

Intake Louver Location

Fresh-air louvers should draw relatively clean outdoor air.

Exhaust Louver Location

Exhaust outlets should be positioned away from sensitive occupied areas where practical.

Preventing Exhaust Air Recirculation

Intake and exhaust openings should be adequately separated to prevent polluted air from returning to the basement.

Basement Pressure & Air Balance

Balancing Fresh Air & Exhaust Air

Supply and exhaust quantities should be coordinated as one system.

Maintaining Controlled Negative Pressure

A slightly negative basement can help prevent pollutants from migrating toward occupied building areas.

Preventing Excessive Negative Pressure

Too much exhaust without sufficient replacement air can create operational problems.

Door Opening Forces

Strong negative pressure can make doors difficult to open.

Ramp Air Movement

Open ramps can introduce or remove significant quantities of air and should be considered during balancing.

Staircase & Lift Lobby Pressure Interaction

Basement exhaust should be coordinated with pressurised escape routes and lift lobbies.

Adjacent Area Air Transfer

Airflow from mechanical rooms, corridors and other basement spaces can affect pressure relationships.

Preventing Pollutant Migration to Occupied Areas

Correct pressure control helps keep vehicle fumes away from lift lobbies, staircases and occupied floors.

Basement Ventilation for Multi-Level Basements

Independent Ventilation for Each Basement Level

Each level can be treated as an individual ventilation zone where required.

Basement-Wise Airflow Calculation

Airflow should reflect the volume and use of each basement.

Common vs Dedicated Ventilation Shafts

Projects may use shared shafts or separate shafts depending on capacity, space and fire zoning.

Zoning of Large Basement Areas

Large floor plates can be divided into multiple ventilation zones.

Fan Capacity for Multiple Levels

Common fans must account for simultaneous demand from connected levels.

CO Monitoring by Basement Level

Separate monitoring improves demand control and fault identification.

Smoke Exhaust Zoning

Fire-mode operation should correspond with the smoke-control zoning strategy.

Balancing Between Basement Levels

Dampers and duct sizing should prevent one level from receiving excessive or inadequate airflow.

Fire Alarm Sequence by Zone

The control system can operate different equipment according to the detected fire zone.

Basement Ramp Ventilation

Vehicle Emissions at Entry & Exit Ramps

Frequent acceleration and queuing can increase local pollutant generation at ramps.

Enclosed Ramp Ventilation

Fully enclosed ramps may require dedicated mechanical ventilation.

Fresh Air Through Ramps

Open ramps can contribute natural make-up air.

Exhaust Air from Ramp Areas

Additional exhaust may be required where fumes collect around enclosed circulation routes.

CO Sensor Placement at Ramps

Sensors near high-traffic ramps can improve detection of local pollution peaks.

Preventing Fume Migration to Ground Floor

Air movement should be controlled so that basement fumes do not travel upward into entrances or public areas.

Airflow Coordination with Parking Levels

Ramp ventilation should operate as part of the wider basement airflow strategy.

Basement Fire & Smoke Safety

Basement Compartmentation

Ventilation systems should coordinate with fire compartments and smoke zones.

Smoke Exhaust System

Mechanical smoke exhaust can help manage smoke during defined fire scenarios.

Fresh Air / Make-Up Air During Fire

Smoke exhaust requires an appropriate source of replacement air.

Fire-Rated Smoke Exhaust Fans

Fans should meet the specified fire-mode operating duty where required.

Fire-Rated Ductwork & Shafts

Smoke pathways should maintain the fire-resistance requirements of the approved system.

Fire & Smoke Dampers

Dampers control airflow between fire compartments according to the intended sequence.

Staircase Pressurisation Coordination

Smoke exhaust should not undermine staircase pressurisation.

Lift Lobby Pressurisation Coordination

Basement ventilation must also be coordinated with protected lift lobby systems.

Fire Alarm Interlocks

Fire detection can automatically trigger the required smoke-control sequence.

Emergency Power Supply

Life-safety ventilation equipment may require emergency electrical supply according to project requirements.

Manual Fireman Override

Manual control can be provided at the designated command centre where required.

Smoke Clearance After Fire

The ventilation system may also assist post-fire smoke clearance according to the approved operational procedure.

Basement Exhaust Standards & Codes

NBC 2016 Basement Ventilation Requirements

Basement mechanical ventilation should be coordinated with applicable NBC requirements and the approved project design.

NBC 2016 Fire & Life Safety Requirements

Fire-mode operation, smoke management, compartmentation and life-safety interfaces should align with the building fire strategy.

NBC 2016 Mechanical Ventilation Requirements

Mechanical ventilation provisions should be reviewed for the specific building and basement application.

NBC Requirements for Smoke Exhaust

Smoke-exhaust requirements should be confirmed against the applicable project criteria and authority approvals.

ASHRAE Guidelines for Enclosed Parking Facilities

ASHRAE guidance may form part of the consultant's design basis for parking-garage ventilation and contaminant control.

CO & Vehicle Contaminant Control Requirements

Sensor thresholds and ventilation sequences should follow the applicable project and regulatory criteria.

Applicable State Fire Service Requirements

Fire-service requirements can vary by location and building type.

Local Municipal Building Regulations

Basement ventilation should also reflect the approved local building regulations.

Applicable Pollution Control Requirements

Exhaust discharge and environmental considerations should be reviewed where relevant to the project.

Basement Exhaust for Different Building Applications

Residential Towers

Residential towers often require multi-level parking ventilation with quiet and energy-efficient operation.

Commercial Buildings

Commercial developments require dependable parking ventilation integrated with the building controls.

Office Buildings

Office basements may experience concentrated arrival and departure periods, making demand-controlled ventilation useful.

Shopping Malls

Mall parking areas can have large floor plates, high traffic and complex smoke-control requirements.

Hotels

Hotel basements require reliable ventilation with consideration for guest comfort and noise.

Hospitals

Hospitals require dependable basement ventilation integrated with critical building systems.

IT Parks

Large IT campuses may contain extensive underground parking requiring multiple ventilation zones.

Data Centres

Data-centre basements can combine parking and critical plant areas requiring carefully coordinated ventilation.

Mixed-Use Developments

Mixed-use projects require ventilation systems coordinated with residential, retail and commercial zones.

Airports

Transport facilities can involve large enclosed parking structures and substantial vehicle traffic.

Educational Campuses

Campus basements may serve parking and multiple building services.

Industrial Facilities

Industrial basements may require heavy-duty fans and additional contaminant-control measures.

Warehouses & Logistics Buildings

Basement or enclosed loading areas require ventilation suited to vehicle movement and operating hours.

Basement Exhaust for Areas Beyond Car Parking

Electrical Rooms

Electrical rooms may require heat-removal ventilation depending on equipment loading and room conditions.

Pump Rooms

Pump rooms can require mechanical ventilation for heat and stale-air removal.

STP Areas

STP spaces can require dedicated extraction because of odour and gas concerns.

Utility Rooms

Various basement utilities may require separate ventilation zones.

Storage Areas

Enclosed storage areas may require ventilation depending on stored materials and occupancy.

Battery Rooms

Battery-room ventilation requires application-specific consideration of potential gases and equipment requirements.

Mechanical Rooms

Mechanical plant rooms may need dedicated supply and exhaust ventilation.

Waste Handling Areas

Garbage and waste rooms typically require dedicated exhaust to control odours.

Maintenance Areas

Workshops and maintenance spaces may generate heat, fumes or other contaminants requiring extraction.

Other Enclosed Basement Service Areas

Compress India can design dedicated ventilation solutions for other enclosed plant and service spaces according to their specific heat and contaminant loads.

Energy Efficiency in Basement Exhaust Systems

CO-Based Demand-Controlled Ventilation

Fans can run according to measured CO rather than continuously at full airflow.

NO2-Based Demand-Controlled Ventilation

NO₂ readings can provide another input to ventilation demand.

VFD-Controlled Exhaust Fans

VFDs allow fan speed to reduce during low-load periods.

Fan Staging

Multiple fans can operate in stages according to demand.

High-Efficiency Fan Selection

Efficient fans reduce long-term electrical consumption.

IE3 & High-Efficiency Motors

High-efficiency motors can further improve energy performance.

Reducing Fan Speed During Low Occupancy

Parking ventilation demand is often lower when vehicle movement is limited.

Low-Pressure-Drop Ductwork

Efficient duct routing reduces required fan pressure.

Low-Pressure-Drop Louvers

Properly sized louvers reduce unnecessary resistance.

Optimised Jet Fan Operation

Jet fans can be staged or controlled according to zone demand.

BMS Scheduling

Building management systems can coordinate operating periods and ventilation modes.

Basement Exhaust Controls & Automation

CO Sensor-Based Fan Control

Fan operation can respond automatically to carbon monoxide levels.

NO2 Sensor-Based Fan Control

NO₂ monitoring can provide additional control where required.

Multi-Speed Fan Operation

Fans can operate at different speeds for low and high ventilation demand.

VFD Fan Speed Control

A Car Park Ventilation VFD allows continuously adjustable airflow.

Zone-Based Ventilation Control

Only affected basement zones may need increased ventilation during normal operation.

Jet Fan Sequencing

Jet fans can start in predefined groups to create the intended airflow path.

Fire Alarm Integration

A fire signal can override normal ventilation operation.

Automatic Fire Mode Operation

Fans, dampers and jet fans can switch automatically to the approved emergency sequence.

Motorised Damper Interlocks

Damper position can be coordinated with fan operation.

Fan Failure Alarms

Fan run status can be monitored and reported to facility teams.

High CO & NO2 Alarms

Pollutant alarms notify operators when concentrations exceed configured limits.

BMS Monitoring & Integration

Fan status, sensor readings, VFD speed and alarms can be monitored through the BMS.

Manual Override from Fire Command Centre

Life-safety equipment can include manual override controls according to the approved fire strategy.

Benefits of a Properly Designed Basement Exhaust System

Better Indoor Air Quality

Fresh-air supply and contaminant extraction create healthier basement conditions.

Effective CO & NO2 Removal

Controlled ventilation reduces accumulation of vehicle pollutants.

Reduced Vehicle Fume Build-Up

Air movement prevents fumes from remaining concentrated around parking lanes and ramps.

Improved Air Movement

Good distribution reduces stagnant regions.

Better Smoke Control During Fire

A coordinated Basement Smoke Exhaust System supports the project's smoke-control strategy.

Improved Occupant Safety

Better pollutant and smoke management improves conditions for basement users.

Reduced Energy Consumption

Demand-controlled ventilation can reduce unnecessary fan operation.

Better Ventilation Control

Sensors, VFDs and zoning provide more responsive operation.

Improved Fire Safety Integration

Ventilation can operate automatically with the building's fire systems.

Compliance with Building Requirements

Professional design supports compliance with the applicable project, building and fire criteria.

Basement Exhaust Installation Guide

Site Survey & Basement Layout Review

The installation process begins with reviewing floor plans, ceiling heights, ramps, parking bays and service zones.

Ventilation Airflow Calculations

Required airflow and fan capacities are confirmed before equipment selection.

Exhaust Fan Installation

Fans should have proper structural support, access and vibration isolation.

Fresh Air Fan Installation

Supply fans should be installed to deliver the calculated fresh-air quantity.

Jet Fan Installation

Jet-fan orientation and mounting height should match the approved airflow design.

Exhaust Duct Installation

Exhaust ducts are installed according to the coordinated routing.

Fresh Air Duct Installation

Fresh-air ducts should maintain required vehicle clearances.

Ventilation Shaft Coordination

Shaft connections should be sealed and coordinated with each basement level.

Louver Installation

Louvers should retain their intended effective free area after installation.

Fire & Smoke Damper Installation

Dampers should be installed according to the approved fire and smoke-control strategy.

CO & NO2 Sensor Installation

Sensors should be mounted at planned locations and commissioned before handover.

VFD & Control Panel Installation

Control equipment should be installed with appropriate electrical protection and access.

Fire Alarm Integration

All emergency operating sequences should be coordinated with the fire alarm system.

BMS Integration

Operating status and alarms can be connected to the building management system.

Electrical Wiring & Interlocks

Fans, dampers, sensors and controls should operate according to the approved sequence.

Testing & Commissioning

Exhaust Airflow Measurement

Actual exhaust airflow should be measured and compared with design quantities.

Fresh Airflow Measurement

Fresh-air delivery should also be verified.

Air Changes per Hour Verification

Measured airflow can be used to confirm achieved air-change performance.

Basement Pressure Measurement

Pressure relationships help identify excessive negative or positive pressure.

Airflow Distribution Testing

Testing can determine whether air is reaching all intended zones.

Dead Zone Identification

Low-air-movement regions can be identified and corrected.

CO Sensor Testing

CO sensors and associated fan-control sequences should be functionally tested.

NO2 Sensor Testing

NO₂ sensors should also be tested where installed.

Jet Fan Direction & Thrust Verification

Jet fans should be checked for correct rotation, orientation and operation.

Exhaust Fan Static Pressure Testing

Static pressure readings can help verify fan operating conditions.

VFD Operation Testing

Minimum, intermediate and high-speed operation should be checked according to the control strategy.

Fire Alarm Interlock Testing

A simulated fire signal can verify correct system changeover.

Smoke Exhaust Mode Testing

Fire-mode fan, damper and jet-fan sequences should be verified according to the approved commissioning procedure.

Motorised Damper Testing

Dampers should open and close completely according to commands.

Emergency Power Operation Testing

Where applicable, life-safety ventilation should be verified under the designated emergency-power condition.

Noise & Vibration Checks

Abnormal fan vibration or excessive noise should be corrected.

Final Testing & Commissioning Report

Where included in scope, Compress India can document commissioning readings, control checks and observed system performance.

Basement Exhaust Service, Maintenance & AMC

Exhaust Fan Inspection

Fans should be inspected for airflow, noise, vibration and mechanical condition.

Fresh Air Fan Inspection

Supply-fan performance should also be checked periodically.

Jet Fan Inspection

Jet fans require inspection of mounting, direction, electrical operation and physical condition.

Fan Belt & Bearing Checks

Belt-driven fans require belt tension, alignment and bearing inspection.

Motor Inspection

Motors should be checked for abnormal temperature, vibration and electrical condition.

Duct & Grille Cleaning

Dust accumulation can restrict airflow and degrade ventilation performance.

Louver Cleaning

Dirty screens and louvers can increase pressure drop.

Damper Inspection

Motorised, smoke and balancing dampers should remain operational and accessible.

CO Sensor Calibration

Regular calibration helps maintain reliable CO-based ventilation control.

NO2 Sensor Calibration

NO₂ sensors also require scheduled checking and calibration.

VFD & Control Panel Checks

Drive parameters, electrical terminals and alarms should be periodically reviewed.

Fire Alarm Interlock Testing

Emergency ventilation sequences should be periodically tested according to the maintenance plan.

Airflow & ACH Verification

Periodic airflow measurement can identify fan or duct deterioration.

Preventive Maintenance & AMC

Compress India offers Basement Exhaust Maintenance and AMC for suitable commercial, residential and industrial ventilation installations.

Common Basement Exhaust Problems & Solutions

High Carbon Monoxide Levels

High CO may result from inadequate airflow, failed fans, incorrect sensor operation or poor air distribution.

Vehicle Fumes Accumulating in the Basement

Fume build-up can indicate insufficient fresh air, inadequate exhaust capacity or stagnant zones.

Weak Exhaust Airflow

Dirty filters or louvers, fan problems, restrictive ducts and incorrect damper positions can reduce extraction.

Insufficient Fresh Air

Undersized shafts or supply fans can limit replacement airflow.

Dead Air Zones

Areas behind columns or far from fans may require air-distribution modifications or additional jet fans.

Poor Air Movement Around Columns

Jet-fan direction or duct outlets may need repositioning to overcome structural obstructions.

Supply & Exhaust Air Short-Circuiting

Poorly located supply and exhaust points can cause fresh air to leave before ventilating the parking area.

Excessive Basement Negative Pressure

Insufficient make-up air can create strong negative pressure and door-opening problems.

Polluted Air Entering Lift Lobbies or Staircases

Pressure imbalance can allow fumes to migrate toward occupied circulation areas.

Exhaust Fan Noise & Vibration

Common causes include fan imbalance, loose mounting, bearing problems or unsuitable operating speed.

Jet Fans Not Moving Air Effectively

Incorrect orientation, beam obstruction or unsuitable spacing can reduce jet-fan effectiveness.

CO Sensors Giving Incorrect Readings

Sensors may require calibration, relocation or replacement.

Fans Running Continuously

The control sequence, sensors or VFD logic may require correction.

High Ventilation Energy Consumption

Continuous full-speed operation can consume unnecessary energy where demand control would be suitable.

Exhaust Air Re-Entering the Building

The external discharge and fresh-air intake arrangement should be reviewed.

Inadequate Smoke Exhaust Performance

Smoke-fan capacity, damper position, make-up air and control sequences should be checked.

Fan Failure During Fire Mode

Fire-mode equipment, controls, emergency supply and interlocks require immediate investigation.

Compress India can inspect existing systems, measure airflow and pressure, test sensors and controls, and recommend corrective modifications.

Basement Exhaust Retrofit & Upgrades

Increasing Exhaust Airflow Capacity

Existing fans or duct systems can be upgraded where measured airflow is inadequate.

Adding Fresh Air Supply

Mechanical fresh air can be introduced where excessive negative pressure exists.

Adding CO & NO2 Sensors

Sensor-based monitoring can improve both air quality and energy efficiency.

Converting Constant Ventilation to Demand-Controlled Ventilation

Existing full-speed systems can potentially be upgraded to sensor-driven operation.

Adding VFD Controls

VFDs allow existing fans to run at variable speed.

Installing Jet Fans

Jet fans can improve air distribution and address stagnant areas in suitable basements.

Correcting Dead Air Zones

Additional grilles, duct modifications or jet-fan changes can improve low-airflow zones.

Modifying Exhaust & Fresh Air Ductwork

Poorly positioned or undersized ducts can be altered to improve performance.

Increasing Shaft Capacity

Where practical, shaft or opening capacity can be increased when existing airflow is restricted.

Upgrading Smoke Exhaust Fans

Existing fans can be replaced to meet revised smoke-exhaust requirements where appropriate.

Adding Fire-Rated Fans

Fans serving emergency smoke duty can be upgraded according to the approved design.

Improving Fire Alarm Integration

Existing systems can be modified to provide more reliable automatic fire-mode operation.

Upgrading BMS Controls

Additional monitoring, alarms and zone control can be integrated.

Rebalancing Existing Basement Ventilation

After modifications, airflow can be measured and redistributed between zones.

Basement Exhaust System Cost in India

The Basement Exhaust System Price in India depends on basement area, number of parking levels, required airflow, system type, ductwork, jet fans, shafts, sensors, fire-mode requirements and controls.

A small mechanical exhaust arrangement and a multi-level Basement Car Park Ventilation System with jet fans and smoke-control operation have very different costs.

Compress India prepares project-specific quotations after reviewing the basement layout and engineering requirements.

Exhaust Fan Cost

Pricing depends on airflow, static pressure, construction, fire rating, motor rating and fan type.

Fresh Air Fan Cost

Supply-fan cost varies according to required airflow and pressure.

Jet Fan Cost

Jet-fan pricing depends on thrust, motor configuration, fire rating where required and project quantity.

Exhaust & Fresh Air Ductwork Cost

Duct cost depends on sizes, total quantity, sheet thickness, fittings, supports and installation height.

Ventilation Shaft & Louver Cost

Cost varies with shaft dimensions, louver free area, material and building integration.

CO & NO2 Sensor Cost

Sensor quantity depends on zoning, basement area and control philosophy.

VFD & Control Panel Cost

Controls depend on fan quantity, motor size, sensors, automation level and BMS requirements.

Fire-Rated Smoke Exhaust System Cost

Fire-mode cost depends on rated fans, smoke ducts, dampers, power arrangements and control requirements.

Installation & Commissioning Cost

Working height, access, basement depth and project complexity influence installation cost.

AMC & Maintenance Cost

AMC cost depends on equipment quantity, sensor calibration requirements and inspection frequency.

Factors Affecting Total Basement Exhaust System Cost

Important factors include:

Basement area and volume, number of levels, parking capacity, normal ventilation airflow, smoke-exhaust airflow, ducted versus jet-fan design, fan static pressure, shaft availability, fire rating, CO and NO₂ sensors, VFDs, fire alarm integration, BMS integration, ductwork quantity and site accessibility.

Send Compress India your basement drawings and project requirements for an accurate quotation.

Basement Exhaust System Design & Installation in Mumbai, Navi Mumbai & Thane

Compress India provides Basement Exhaust System Design and Installation in Mumbai, Navi Mumbai and Thane for residential towers, offices, hotels, hospitals, shopping malls, IT parks, industrial buildings, warehouses and mixed-use developments.

Our scope can include normal basement ventilation, parking exhaust, mechanical fresh air, CO and NO₂ monitoring, jet-fan ventilation, smoke extraction, ductwork, shafts, louvers, VFDs, control panels, fire alarm integration, BMS integration, installation, testing and AMC.

We also undertake retrofit projects where existing basements experience high pollutant levels, poor air movement, excessive fan energy consumption or inadequate smoke-control performance.

For a new project, share your architectural and parking drawings.

For an existing installation, provide fan details, basement plans and a description of the problem so our team can evaluate the next step.

Why Choose Compress India for Basement Exhaust Systems?

Basement Ventilation Engineering Expertise

Compress India approaches Basement Exhaust Systems as complete airflow and contaminant-control solutions.

Airflow & ACH Calculations

Ventilation airflow is calculated according to project size, use and design requirements.

CO & NO2 Ventilation Design

Sensor-based pollutant monitoring can be integrated into the ventilation strategy.

Smoke Exhaust Engineering

Normal ventilation and emergency smoke mode can be coordinated as part of the overall system design.

Jet Fan & Air Distribution Design

We can develop directional airflow arrangements using jet and impulse fans where appropriate.

CFD Analysis Support

Complex projects can be supported with CFD-based evaluation where required.

Exhaust & Fresh Air Ductwork Execution

Compress India can coordinate fabrication and installation of mechanical ventilation ductwork.

Fan, Shaft & Louver Selection

Equipment is selected according to airflow, static pressure, velocity, fire duty and architectural constraints.

Fire Alarm & BMS Integration

Ventilation controls can interface with fire and building-management systems.

Testing & Commissioning

We can verify airflow, pressure, fan operation, sensors and emergency control sequences.

Retrofit & Performance Improvement

Existing systems can be measured and upgraded instead of automatically being replaced.

Preventive Maintenance & AMC Support

Ongoing inspections, sensor calibration and fan maintenance help preserve system performance.

Get a Basement Exhaust Solution from Compress India

Whether you require a new Underground Parking Exhaust Ventilation System, a ducted basement exhaust arrangement, jet-fan ventilation or an upgrade to an existing basement, Compress India can develop a solution around your building requirements.

Our services can include:

Basement ventilation design Basement exhaust CFM calculation Fresh air systems Basement exhaust fans Jet fans and impulse ventilation CO and NO₂ monitoring VFD controls Ductwork and shafts Smoke exhaust Fire-rated fans Fire alarm integration BMS integration CFD support Installation Testing and commissioning Retrofit improvements Preventive maintenance and AMC

Contact Compress India with your project drawings and requirements for a technical review and quotation.

Connect with Our HVAC & Ventilation Team

For a new basement project, share:

Building type Basement floor plans Number of basement levels Parking capacity Basement floor-to-floor height Fresh-air openings Available shafts Fire and smoke-control requirements Project location

For an existing system, also share fan details, sensor information, airflow problems and any available commissioning data.

Compress India also provides related solutions for: Mechanical exhaust ventilation Commercial ventilation systems Smoke exhaust systems Fresh air systems Jet fan ventilation Car park ventilation Plant room ventilation Electrical room ventilation DG room ventilation Industrial ventilation Ductwork fabrication and installation Ventilation control and BMS integration

Toilet Exhaust Ventilation Systems

Toilet Exhaust Ventilation Systems

Learn More
Kitchen Exhaust Systems

Kitchen Exhaust Systems

Learn More
DG Room Ventilation Systems

DG Room Ventilation Systems

Learn More
Electrical Room Ventilation

Electrical Room Ventilation

Learn More
Laboratory Exhaust Systems

Laboratory Exhaust Systems

Learn More

Frequently Asked Questions

Q1: What is a basement exhaust system?

A Basement Exhaust System is a mechanical ventilation arrangement that removes vehicle fumes, stale air and other contaminants from enclosed basement areas while introducing replacement fresh air.

In parking basements, the system commonly includes exhaust fans, supply fans, ducts or jet fans, CO sensors and automatic controls.

Q2: Why is mechanical ventilation required in basement parking areas?

Underground parking has limited natural airflow.

Vehicle exhaust can therefore accumulate unless contaminated air is removed and replaced with outdoor air.

Mechanical ventilation also supports smoke-management operation during fire emergencies where required by the approved design.

Q3: How is basement exhaust airflow or CFM calculated?

Basement Exhaust CFM Calculation considers basement volume, ventilation criteria, vehicle activity, contaminant control, smoke-exhaust requirements, zoning and applicable project standards.

Duct and shaft pressure losses are then calculated so that the fans can be selected at the required duty point.

Q4: How many air changes per hour are required for basement ventilation?

The required Basement Ventilation ACH depends on operating mode, building design, applicable requirements and whether the calculation relates to normal contaminant ventilation or emergency smoke exhaust.

The correct value should therefore be established from the project's applicable design criteria rather than applying one ACH figure to every basement.

Q5: How are carbon monoxide levels controlled in basement parking areas?

CO sensors continuously monitor representative parking zones.

The control system can start, stage or modulate exhaust and fresh-air fans when pollutant concentration rises.

A Basement Ventilation System with CO Sensors can therefore reduce both pollutant levels and unnecessary full-speed fan operation.

Q6: What is the role of jet fans in basement ventilation?

Jet fans create directional air movement across the parking area.

Instead of collecting all contaminated air through extensive horizontal ductwork, a Car Park Ventilation System with Jet Fans uses thrust to move polluted air toward designated exhaust points or shafts.

Q7: What is the difference between normal basement ventilation and smoke exhaust?

Normal basement ventilation removes everyday vehicle pollutants and stale air.

Smoke exhaust is an emergency operating mode intended to manage smoke during a fire according to the approved fire strategy.

The required airflow, fan operation and control sequence may differ substantially between the two modes.

Q8: How does a basement smoke exhaust system work during a fire?

When the fire alarm activates the relevant sequence, selected smoke-exhaust fans, jet fans and motorised dampers can switch to fire mode.

Smoke is directed toward designated extraction points while replacement air enters through the planned make-up air path.

The exact sequence depends on the project's approved smoke-control design.

Q9: Why are CO and NO2 sensors used in basement parking ventilation?

CO and NO₂ sensors measure vehicle-related contaminants.

They allow ventilation to respond to actual air quality rather than operating continuously at maximum capacity.

This supports safer contaminant control and improved energy efficiency.

Q10: What are the NBC 2016 requirements for basement exhaust and smoke ventilation?

Basement ventilation should be designed in accordance with the applicable NBC provisions, fire and life-safety requirements, local authority requirements and the project's approved fire strategy.

Normal ventilation and smoke-exhaust requirements should be evaluated separately where required.

Q11: What is the cost of a basement exhaust system in India?

The Basement Exhaust System Cost in India depends on basement size, number of levels, airflow, fan capacity, ductwork, shafts, jet fans, CO and NO₂ sensors, VFDs, smoke-control requirements and automation.

Compress India can provide project-specific pricing after reviewing your basement drawings and design requirements.

Q12: Does Compress India design and install basement exhaust systems in Mumbai, Navi Mumbai and Thane?

Yes. Compress India provides Basement Exhaust Systems in Mumbai, Navi Mumbai and Thane, including design, airflow calculations, exhaust fans, fresh-air systems, jet fans, ductwork, shafts, CO and NO₂ monitoring, smoke exhaust, controls, installation, testing, commissioning, retrofit and AMC.