Laboratory Exhaust Systems
Design, Supply, Installation, Testing, Certification & AMC for Laboratory Ventilation & Fume Exhaust
Design, Supply, Installation, Testing, Certification & AMC for Laboratory Ventilation & Fume Exhaust
Compress India designs, supplies, installs, tests and maintains laboratory exhaust systems that keep researchers safe, contain hazardous fumes and hold every room at the right pressure. From a single ducted fume hood to a complete exhaust system for a multi-floor research building, we take responsibility for the whole air path: capture at the hood, chemical-resistant ductwork, laboratory exhaust fans and stacks, make-up air, and the controls that tie them together.

Our laboratory ventilation team works with pharmaceutical QC and R&D labs, hospitals, universities, research institutes and testing laboratories. Every lab exhaust system we build is designed around your chemical inventory and risk assessment, tested against recognised standards such as ANSI/ASSP Z9.5 and ASHRAE 110, and handed over with documentation prepared for audits and accreditation reviews.
- Laboratory exhaust system design, CFM calculation and fan sizing
- Supply and installation of fume hood exhaust, PP and SS ductwork, scrubbers and high-plume fans
- Laboratory exhaust systems with negative pressure, VAV control and redundant fans
- Testing, commissioning, certification support and annual maintenance contracts (AMC)
Planning a new lab, upgrading an old fume hood exhaust system or struggling with failed face velocity tests? Share your lab layout with our HVAC team for a site survey and a detailed quotation.
What Is a Laboratory Exhaust System?
A laboratory exhaust system is the engineered ventilation network that captures hazardous fumes, vapours, gases and aerosols at their source and discharges them safely above the building. It combines laboratory local exhaust ventilation (LEV) – fume hoods, biosafety cabinets, snorkel arms and canopy hoods – with general room exhaust, corrosion-resistant ductwork, laboratory exhaust fans, exhaust stacks and airflow controls.
Unlike comfort air conditioning, a laboratory ventilation system normally runs on 100% fresh air, with no recirculation of lab air. The exhaust side sets the pace, and supply air follows it so the lab stays at negative pressure relative to corridors and offices. A simple wall-mounted exhaust fan in a laboratory cannot do this; it neither captures fumes at the bench nor controls where contaminated air goes.
A well-engineered laboratory mechanical ventilation system therefore does three jobs at once: it protects people, protects the building and protects the work being done inside.
Why Laboratories Need a Dedicated Exhaust System
Lab air cannot be handled by a building's general HVAC. It carries chemical vapours, acid mists, solvents and sometimes infectious aerosols that must never return to occupied spaces. A dedicated laboratory exhaust system is the primary engineering control that keeps those hazards contained.
Protecting Researchers from Hazardous Fumes
Fume hoods and local exhaust capture toxic, flammable and corrosive vapours before they reach the user's breathing zone. Effective capture keeps exposure well below occupational limits and protects the chemists, analysts and technicians who spend full shifts at the bench.
Containing Chemical & Biological Hazards
Chemical fume hood exhaust handles solvents, acids and reactive compounds, while biosafety cabinet exhaust contains infectious aerosols through HEPA filtration. A dedicated hazardous laboratory exhaust keeps these streams separate from general building air, with the right duct materials, filtration and treatment for each hazard.
Maintaining Safe Room Pressure Relationships
Labs are held at negative pressure so air flows from clean corridors into the lab, never the other way. The exhaust system, working with supply air tracking, creates this inward airflow and stops odours and contaminants from migrating into offices, write-up areas and public spaces.
Protecting Samples & Experiments
Stable airflow, low cross-drafts and controlled pressure protect sensitive samples, analytical instruments and weighing operations. In microbiology and cell culture areas, correctly connected biosafety cabinets give product protection as well as personnel protection, reducing contamination and repeat work.
Meeting Safety & Accreditation Requirements
Regulators, accreditation bodies and corporate EHS teams expect documented ventilation performance. A properly engineered laboratory exhaust system, backed by face velocity data, containment tests and pressure records, supports GMP audits, NABL assessments, biosafety certification and insurance inspections.
How a Laboratory Exhaust System Works
Every laboratory exhaust system follows the same path: capture at the source, transport through sealed ducts, safe discharge high above the roof, and supply air that follows the exhaust to keep the lab negative.
1. Fume Hoods & Local Exhaust Capture Contaminants
Fume hoods, biosafety cabinets, snorkel arms and ventilated cabinets draw air inward at controlled velocities, capturing fumes where they are generated. This laboratory fume extraction at source does most of the safety work, which is why hood selection and face velocity are designed first.
2. General Room Exhaust Maintains Air Changes
Ceiling or low-level exhaust grilles remove heat and any escaped vapours from the room, keeping the lab at its design air changes per hour (ACH). In labs with many fume hoods, hood exhaust alone often satisfies the ACH requirement; in labs with few hoods, general exhaust makes up the difference.
3. Corrosion-Resistant Ducts Carry Exhaust Air
Exhaust air travels through chemical-resistant ductwork – polypropylene (PP), stainless steel (SS) or coated steel – sized to keep vapours and condensate moving. Ducts inside the building run under negative pressure, so any leak draws room air in rather than pushing fumes out.
4. Exhaust Fans Discharge Air Through High Stacks
Laboratory roof exhaust fans, usually corrosion-resistant centrifugal or mixed flow designs, push the air out through a vertical laboratory exhaust stack. High-plume fans add entrained outside air and high discharge velocity so the plume rises clear of the roof and away from fresh air intakes.
5. Supply Air Tracks Exhaust to Keep the Lab Negative
A make-up air unit delivers conditioned 100% fresh air. Airflow controls hold supply slightly below exhaust – the airflow offset – so the lab stays at negative pressure even as fume hood sashes open and close throughout the day.
Main Components of a Laboratory Exhaust System
A lab exhaust system is only as reliable as its weakest component. Compress India selects, supplies and integrates each element below as one coordinated system rather than a collection of separate purchases.
Fume Hoods
Ducted fume hoods are the primary chemical ventilation hood in most labs. We supply and connect bench-top, floor-mounted, walk-in and specialist hoods with liners, baffles and sashes suited to your chemistry, complete with fume hood exhaust connections and airflow monitoring.
Biosafety Cabinets
Biosafety cabinets protect users, samples and the environment when handling biological material. Their exhaust connection – canopy (thimble) or hard-ducted – must match the cabinet class and type, and the building exhaust must be sized and controlled to suit.
Canopy Hoods & Snorkel Exhaust Arms
Canopy hoods capture heat and steam above ovens, autoclaves and furnaces. Snorkel exhaust arms, often called elephant trunk fume hoods, provide flexible spot extraction over AAS, ICP and GC instruments and small bench processes. Both are practical extraction hood lab solutions, but neither replaces a fume hood for work with toxic chemicals.
Ventilated Chemical Storage Cabinets
Acid, corrosive and solvent storage cabinets can be connected to the exhaust to remove vapours from stored containers. Flammable storage cabinets need particular care with duct material and fire separation, and should be vented only where the risk assessment or local authority requires it.
Exhaust Ductwork (PP, SS & Coated)
PP ducting resists most acids and alkalis and is widely used for general chemical exhaust, with flame-retardant grades available where fire codes demand them. Stainless steel suits high-temperature, solvent and perchloric acid duty and gives a robust stainless steel exhaust system where fire performance matters. Epoxy- or PVDF-coated steel offers a middle ground. We specify laboratory chemical resistant ductwork from your chemical inventory, not from habit.
Airflow Control Valves
Venturi or blade-type airflow control valves hold exhaust and supply volumes at their set points as sashes move and duct static pressure changes. They are central to both VAV laboratory exhaust and constant volume laboratory exhaust, keeping flows accurate without repeated rebalancing.
High-Plume Exhaust Fans & Stacks
High-plume laboratory exhaust fans entrain outside air and discharge the mixture at high velocity, lifting the plume well above the roof line without very tall stacks. For smaller labs, corrosion-resistant FRP or PP centrifugal lab hood exhaust fans with properly designed stacks remain a cost-effective choice.
High-plume vs standard exhaust fan comes down to how dispersion is achieved: a standard laboratory centrifugal exhaust fan relies mainly on stack height, while a high-plume fan relies on discharge velocity and dilution.
HEPA, Carbon Filters & Scrubbers
A laboratory exhaust HEPA filter removes biological particulates from BSC and BSL-3 exhaust. Laboratory activated carbon exhaust filters adsorb organic vapours where discharge limits apply. Wet scrubbers neutralise acid fumes before discharge; a laboratory exhaust scrubber is common for acid digestion, metals analysis and perchloric acid work.
Fume Hood Monitors & Room Pressure Monitors
A fume hood airflow monitor displays face velocity and alarms when it drops below a safe limit. Room pressure monitors confirm the lab stays negative and alarm on door-open or system faults. Together they give users and facility teams real-time confidence that the system is working.
Types of Laboratory Fume Hoods
The right lab ventilation hood depends on your chemistry, frequency of use, energy budget and building systems. These are the main fume hood types we supply, connect and test.
Constant Air Volume (CAV) Fume Hoods
A CAV hood exhausts the same air volume whatever the sash position. It is simple and dependable, but in conventional designs face velocity rises sharply as the sash closes, and energy use stays high around the clock.
Bypass Fume Hoods
A bypass hood opens an air path above the sash as it closes, keeping exhaust volume constant while preventing excessive face velocity. It is a widely used constant volume design and works well with simple, single-speed exhaust fans.
Variable Air Volume (VAV) Fume Hoods
VAV hoods sense sash position or face velocity and adjust exhaust volume to hold a steady face velocity. When the sash is lowered, exhaust drops, and so does the conditioned make-up air the building must supply. VAV is the foundation of energy efficient laboratory exhaust.
Low-Flow High-Performance Fume Hoods
Aerodynamic profiles, airfoil sills and optimised baffles let high-performance hoods contain fumes at lower face velocities, provided containment is verified by ASHRAE 110 or EN 14175 testing. They reduce exhaust volume without reducing protection.
Walk-In & Distillation Fume Hoods
Walk-in hoods sit at floor level for large apparatus, pilot rigs and drums. Distillation hoods have a lowered work surface for tall glassware assemblies. Both need larger exhaust volumes and careful sash arrangements to control face velocity.
Perchloric Acid Fume Hoods
Heated perchloric acid can leave shock-sensitive perchlorate deposits in hoods and ducts. These hoods use stainless steel or other non-reactive construction, an integral wash-down system and a dedicated, straight, vertical perchloric acid fume hood exhaust that is never manifolded with other hoods.
Ductless (Filtered) Fume Hoods
Ductless hoods pass air through carbon or HEPA filters and return it to the room. They suit small, well-defined, low-volume tasks but are not appropriate for unknown, highly toxic or high-volume chemical work, and they need strict filter monitoring and replacement.
Biosafety Cabinets & Their Exhaust Connections
Biosafety cabinet exhaust must match the cabinet's class and type. The wrong connection can upset the cabinet's internal airflow balance and compromise protection, so we design the cabinet and the building exhaust together.
Class I Biosafety Cabinets
Class I cabinets draw room air in through the front opening and exhaust it through a HEPA filter. They protect the user and the environment but not the sample, and can be room-exhausted or ducted depending on the materials handled.
Class II A2 Cabinets (Canopy / Thimble Connection)
A2 cabinets recirculate about 70% of their HEPA-filtered air within the cabinet and exhaust about 30%. Where small amounts of volatile chemicals are used, they connect to the building exhaust through a canopy (thimble) connection – an air gap that lets the cabinet keep its own balance even if building exhaust fluctuates. The canopy must be alarmed so users know immediately if exhaust is lost.
Class II B1 & B2 Cabinets (Hard-Ducted Exhaust)
B1 cabinets exhaust the majority of their air through the building system, while B2 cabinets are total-exhaust units that send 100% of their air outdoors with no recirculation. Both must be hard-ducted to a dedicated, reliable exhaust with interlocks and alarms, because any loss of building exhaust directly affects cabinet containment.
Class III Biosafety Cabinets
Class III cabinets are gas-tight glove boxes for the highest-risk agents. Supply air is HEPA-filtered, and exhaust passes through two HEPA filters in series (or HEPA plus incineration) via a dedicated hard-ducted biosafety cabinet exhaust that holds the cabinet under strong negative pressure.
Ducted vs Ductless Fume Hoods
Ducted fume hoods remove contaminants from the building entirely, while ductless hoods filter the air and return it to the room. For most chemistry and pharmaceutical labs, ducted is the safer default.
| Factor | Ducted fume hoods | Ductless (filtered) fume hoods |
|---|---|---|
| How it works | Exhausts fumes outdoors through ductwork and a fan | Filters air through carbon or HEPA media and returns it to the room |
| Chemical range | Broad, including mixtures and unknowns | Limited to chemicals the filter is rated for |
| Volume of work | Continuous and high-volume use | Small quantities, intermittent tasks |
| Installation | Needs a duct route, roof fan and make-up air | Plug-in; minimal building work |
| Running cost | Higher energy for conditioned make-up air | Low energy, but regular filter replacement |
| Monitoring | Face velocity monitor and alarm | Filter saturation monitoring is essential |
| Best for | Chemistry, pharma QC, acid and solvent work | Weighing, teaching demonstrations, light routine tasks |
Not sure which suits your lab? Our engineers will review your chemical list and recommend the safest, most economical option.
Fume Hood vs Biosafety Cabinet
A fume hood protects people from chemicals; a biosafety cabinet protects people, samples and the environment from biological agents. The two are not interchangeable, and choosing the wrong one is a common and serious lab design error.
| Factor | Chemical fume hood | Biosafety cabinet (Class II) |
|---|---|---|
| Primary hazard | Chemical vapours, gases and fumes | Infectious or biological aerosols |
| Filtration | None; exhausts outdoors (ducted type) | HEPA on downflow and exhaust air |
| Sample protection | No | Yes |
| Exhaust connection | Always ducted to outside (ducted type) | Room-recirculated, canopy or hard-ducted, by type |
| Volatile chemicals | Designed for them | Only small amounts, in suitably exhausted types |
| Test standard | ASHRAE 110 / EN 14175 | NSF/ANSI 49 / EN 12469 |
Many labs need both. We design the exhaust so each device works exactly as its maker and the standards intend.
CAV vs VAV Laboratory Exhaust
Constant volume laboratory exhaust runs every hood at full flow all the time; VAV laboratory exhaust matches flow to real demand. The choice shapes both first cost and decades of energy bills.
| Factor | Constant Air Volume (CAV) | Variable Air Volume (VAV) |
|---|---|---|
| Exhaust flow | Fixed at design maximum | Varies with sash position and occupancy |
| Face velocity | Varies with sash (unless bypass type) | Held steady at set point |
| Controls | Balancing dampers | Airflow valves, sash sensors, tracking controls |
| Capital cost | Lower | Higher |
| Energy use | High, 24×7 | Substantially lower when sashes are closed |
| Room pressure | Fixed offset set at balancing | Actively tracked supply-exhaust balance |
| Best fit | Small labs, few hoods, short run hours | Multi-hood labs, long operating hours |
In labs with several hoods running long hours, a laboratory exhaust system with VAV control often pays back through lower fresh-air cooling loads. We prepare a life-cycle comparison before you commit, so the decision is based on your numbers.
Manifolded vs Individual Exhaust Systems
In an individual system, each fume hood has its own duct and fan. In a manifolded laboratory exhaust, many hoods share a common duct, plenum and fan set. Both have a place, and many buildings use both.
| Factor | Individual (dedicated) exhaust | Manifolded (central) exhaust |
|---|---|---|
| Fans | One fan per hood | Shared fan set, often N+1 |
| Redundancy | A fan failure disables that hood | A standby fan keeps every hood running |
| Dilution | None before discharge | Mixed streams dilute before discharge |
| Roof space | Many small fans and stacks | Fewer, larger fans and stacks |
| Energy | Hard to vary efficiently | Works well with VAV and VFDs |
| Flexibility | Easy to add a hood with its own fan | Spare capacity planned for future hoods |
| Required for | Perchloric acid, radioisotopes, incompatible streams | General chemical exhaust in larger buildings |
Individual vs manifolded laboratory exhaust is decided by chemical compatibility, redundancy needs and roof space. We often combine both: a central laboratory exhaust system for general hoods, with dedicated fume hood exhaust for special processes.
Laboratory Exhaust for Different Lab Types
Every lab type has its own hazards, schedules and compliance drivers. We design laboratory exhaust around how your lab actually works, not around a standard template.
Chemistry Laboratories
Synthesis, analytical and wet chemistry labs rely on ducted fume hoods, solvent cabinets and acid-resistant ductwork. A laboratory exhaust system for chemical laboratory work must handle mixed laboratory solvent exhaust and laboratory acid exhaust, with duct materials and fan coatings matched to the chemical inventory.
Pharmaceutical QC & R&D Labs
QC labs run HPLC, GC, dissolution and wet chemistry for long hours, while R&D labs handle potent APIs and new chemistry. Pharmaceutical laboratory exhaust must support GMP documentation, controlled pressure cascades and reliable fan redundancy, often alongside cleanroom laboratory exhaust for adjoining controlled areas.
Microbiology & BSL-2 / BSL-3 Labs
Biosafety laboratory exhaust centres on correctly connected biosafety cabinets, directional airflow and HEPA filtration. BSL-3 facilities add sealed rooms, anterooms, pressure cascades, HEPA-filtered exhaust and redundant fans, designed and validated to Indian containment and certification guidelines.
Hospital & Pathology Labs
Grossing stations, staining areas and tissue processors release formaldehyde and xylene vapours. Hospital laboratory exhaust uses downdraft grossing tables, ducted hoods and local exhaust to keep exposure low in busy diagnostic environments.
Academic & Teaching Labs
University laboratory exhaust must cope with many users, variable timetables and tight budgets. Robust bypass or VAV hoods, clear alarms, occupancy-based setback and easy maintenance access make teaching labs safe and affordable to run.
Food & Environmental Testing Labs
Acid digestion, solvent extraction and sample preparation for food, water and soil testing call for acid-resistant hoods, PP ductwork and, where needed, scrubbers. Snorkel arms over AAS and ICP instruments capture heat and combustion products.
Petroleum & Oil Testing Labs
Flash point, distillation and hydrocarbon testing generate flammable vapours. These labs need distillation or walk-in hoods, spark-resistant fan construction where the hazardous area classification requires it, and careful application of NFPA 45 fire protection principles.
Animal Research Facilities
Vivaria need high air change rates, odour and allergen control, directional airflow and exhaust connections for ventilated cage racks. Exhaust reliability is critical for animal welfare, so N+1 fans and backup power are standard design considerations.
Laboratory Ventilation Standards & Guidelines
Compress India designs and tests laboratory exhaust systems against recognised international standards and Indian biosafety guidelines, and aligns each design with your organisation's own EHS requirements.
ANSI/ASSP Z9.5 Laboratory Ventilation
ANSI/ASSP Z9.5-2022 is the leading reference for laboratory ventilation design, operation and maintenance. It covers the laboratory ventilation management plan, exposure control devices such as fume hoods, exhaust discharge, commissioning and routine testing, and expects new, renovated or modified systems to be commissioned before lab staff use them.
ASHRAE 110 Fume Hood Performance Testing
ANSI/ASHRAE 110 (2016 edition, reaffirmed in 2025) defines how fume hood containment is tested: face velocity measurement, smoke flow visualisation and a tracer gas test with a mannequin at the hood face. Tests can be run as manufactured (AM), as installed (AI) or as used (AU).
EN 14175 Fume Cupboard Standard
EN 14175 is the European fume cupboard standard, with parts covering safety and performance requirements, type testing, on-site testing and variable air volume fume cupboards. Projects specified to EN 14175 verify fume cupboard exhaust performance through containment tests rather than face velocity alone.
NFPA 45 Fire Protection for Laboratories
NFPA 45, currently in its 2024 edition, sets fire protection requirements for laboratories using chemicals, including laboratory ventilating systems and chemical fume hoods. The 2024 edition extended its scope to laboratories in health care facilities where ignitible liquids are present.
NSF/ANSI 49 Biosafety Cabinet Certification
NSF/ANSI 49 governs the design, construction, performance and field certification of Class II biosafety cabinets. The current 2024 edition defines the field tests – inflow and downflow velocity, HEPA filter integrity, airflow smoke patterns and alarm checks – that cabinets must pass at installation and at each recertification.
ICMR & DBT Biosafety Guidelines (India)
In India, the Department of Biotechnology's Regulations and Guidelines on Biosafety of Recombinant DNA Research & Biocontainment (2017), its guidelines for establishing BSL-2 and BSL-3 containment facilities (2020) and its 2024 national guidelines for certifying BSL-3 facilities form the core framework, alongside ICMR guidance for BSL-3 laboratories. The DBT containment guidelines call for at least 12–15 air changes per hour in BSL-3 laboratory areas, together with negative pressure and HEPA-filtered exhaust.
Laboratory Exhaust Design & Sizing
Good laboratory exhaust system design starts with the hazard, not the fan catalogue. Our design process follows ten steps that turn your risk assessment into a safe, efficient and buildable system.
Lab Risk Assessment & Chemical Inventory
We review the chemicals, quantities, processes and biological agents in each room with your EHS team. This defines which areas need fume hoods, biosafety cabinets or special exhaust, which duct materials are required, and whether scrubbers, carbon or HEPA filtration are needed before discharge.
Air Changes per Hour (Occupied & Unoccupied)
Air change rates follow risk, heat load and hood exhaust. Many chemical labs are designed around roughly 6–12 ACH when occupied, with a lower unoccupied rate where the risk assessment allows; BSL-3 and specialist areas follow their own guideline values. Our laboratory exhaust CFM calculation is done room by room, so whichever is highest – hood demand, ACH or cooling need – governs the design.
Fume Hood Face Velocity & Sash Height
Conventional hoods are commonly set at about 0.4–0.5 m/s (80–100 fpm) at the design sash opening, while high-performance hoods may be validated at lower velocities. Fume hood exhaust CFM equals face velocity multiplied by the open sash area: a 1.8 m hood with a 1.6 m × 0.5 m opening at 0.5 m/s exhausts about 0.4 m³/s (roughly 850 CFM). Sash stops and restricted operating heights therefore have a direct effect on fan sizing and energy.
Room Pressurisation & Airflow Offset
Negative pressure is created by exhausting more air than is supplied – the airflow offset. A typical approach sets a fixed offset (often around 10% of exhaust, or a set volume per door) and confirms the result with a laboratory differential pressure reading, which is then monitored continuously in critical rooms.
Supply Diffuser Placement to Avoid Cross Drafts
Supply air blowing across a hood face can pull fumes out of even a correctly sized hood. We place low-velocity diffusers away from hood openings, keep terminal velocities low near the hood face and measure cross-draft velocity during commissioning.
Duct Material & Transport Velocity
Duct material follows the chemistry: PP for acids and general chemical exhaust, SS for heat, solvents and perchloric acid, and coated steel where appropriate. Laboratory exhaust duct velocity is typically held around 5–10 m/s to keep vapours moving and prevent condensate pooling, while keeping laboratory exhaust static pressure and noise under control.
Manifold Design & Fan Redundancy (N+1)
Manifolded systems use a common laboratory exhaust fan plenum held at a constant negative static pressure, with several fans sharing the load. An N+1 laboratory exhaust arrangement keeps a standby fan ready, so one fan can fail or be serviced without losing a single hood. Isolation dampers and automatic changeover complete this high reliability laboratory exhaust design.
Stack Height, Discharge Velocity & Re-Entrainment Prevention
Exhaust must leave the roof fast enough and high enough that it is not drawn back into air intakes, doors or neighbouring buildings. Common practice, consistent with long-standing Z9.5 guidance, is a stack discharging at least 3 m above the adjacent roof line at an exit velocity of around 15 m/s (3,000 fpm) or more, with no rain caps that deflect the plume downward. Laboratory exhaust fan sizing is checked against these discharge targets, not just airflow.
Dispersion Modelling & CFD
For larger buildings, crowded rooftops or sensitive neighbours, we carry out or coordinate laboratory exhaust dispersion studies and CFD modelling to predict plume behaviour in different wind conditions. This confirms stack heights, fan selections and intake locations before construction, when changes cost least.
100% Fresh Make-Up Air & Cooling Load
Every cubic metre of exhausted air must be replaced with conditioned outdoor air. In a hot, humid coastal climate, that laboratory make up air carries a heavy cooling and dehumidification load. We size the make-up air unit, coils and reheat together with the exhaust, so the lab stays comfortable, dry and correctly pressurised.
Energy Efficiency in Laboratory Exhaust
Laboratories use far more energy per square metre than offices, mainly because of 100% fresh air. Energy efficient laboratory exhaust ventilation reduces that load without compromising safety, and every measure below is designed around your risk assessment.
VAV Fume Hoods & Sash Management
VAV hoods reduce exhaust whenever sashes close. Combined with sash closers, high-sash alarms and user awareness, they deliver some of the largest savings in any lab, because every cubic metre not exhausted is a cubic metre of outdoor air not cooled.
Occupancy & Presence Sensors
Presence sensors at the hood face can lower the face velocity set point when no one is working at the hood, within limits set by the risk assessment. Room occupancy sensors trigger reduced air change rates when the lab is empty.
Night-Time Air Change Setback
Many labs stand empty for half of every day. A scheduled or occupancy-based night setback reduces general exhaust and supply to a safe unoccupied rate, while fume hoods and storage cabinets continue to exhaust as required.
Demand-Controlled Lab Ventilation
Demand-controlled ventilation samples lab air for VOCs, particles and CO2 and raises the air change rate only when contaminants are detected. Clean labs run at lower ACH most of the time, while the system responds quickly to a spill.
Heat Recovery with Run-Around Coils & Heat Pipes
Run-around coil loops and heat pipes transfer energy between the exhaust and fresh air streams without any cross-contamination, pre-cooling hot, humid make-up air with cooler lab exhaust. They are a safe choice for lab exhaust, where recovery wheels are generally avoided because of carry-over risk.
Variable-Volume High-Plume Fans
High-plume fans with variable frequency drives and laboratory exhaust bypass air dampers can slow down as VAV hoods turn down, while still maintaining the minimum discharge velocity needed for safe dispersion. A well-tuned laboratory exhaust VFD strategy is one of the most effective fan-side savings available.
Controls, Monitoring & Safety
Controls turn fans and ducts into a laboratory exhaust system you can trust every hour of every day. Laboratory pressure control, alarms and logging are designed in from the start, not added as an afterthought.
Fume Hood Face Velocity Monitors & Alarms
Every fume hood should show its airflow status at a glance. Face velocity monitors display live readings, sound audible and visual alarms on low flow, and can flag high-sash conditions to encourage good working practice.
Room Pressure Monitors
Room pressure monitors measure the pressure difference between the lab and its corridor or anteroom, alarm when negative pressure is lost and log readings for audits. They are essential for BSL-2+ and BSL-3 labs, pharmaceutical suites and high-hazard chemistry areas.
Supply-Exhaust Airflow Tracking
Tracking controls measure total exhaust and adjust supply valves to maintain the designed offset as hoods modulate. This laboratory supply exhaust balance keeps pressure stable and prevents slamming doors and air rushing in from corridors.
Emergency Purge Mode
A clearly labelled emergency purge switch drives the lab to maximum exhaust and minimum supply after a spill or release, clearing the room quickly while increasing negative pressure. This fume hood emergency exhaust function is tested at commissioning and during routine maintenance.
Backup Power for Critical Exhaust
Exhaust fans serving BSCs, BSL-3 suites, toxic gas cabinets and perchloric hoods should be on DG or standby power with automatic restart, so containment returns quickly after a power cut. Monitors and controllers need UPS support to avoid false readings during changeover.
BMS Integration
Laboratory exhaust BMS integration brings fan status, hood alarms, room pressures, energy data and trend logs into one dashboard. Facility teams spot problems early, demonstrate compliance and plan maintenance with real data instead of guesswork.
Benefits of Laboratory Exhaust Systems
A professionally engineered laboratory exhaust system pays back in safety, compliance and running cost throughout the life of the lab.
Researcher Safety
Hazards are controlled at the source, so staff work in a healthier environment. Management gains confidence that the most important engineering control in the lab is performing as designed.
Reliable Containment of Hazards
Tested hoods, alarmed BSC connections and N+1 fans maintain containment through daily use, routine maintenance and equipment failure. Laboratory exhaust redundancy means one fault does not shut down your work.
Compliance with Safety & Accreditation Standards
Documented performance against ANSI/ASSP Z9.5, ASHRAE 110, NSF/ANSI 49 and DBT guidelines supports regulatory inspections, GMP audits and accreditation. Clear records also simplify annual recertification.
Protection of Samples & Instruments
Stable airflow and controlled pressure reduce sample contamination and corrosion of costly instruments. Fewer failed runs mean less repeat testing and better use of lab time.
Safe Dispersion of Exhaust
High-plume fans and correctly designed stacks carry exhaust clear of your roof, fresh air intakes and neighbours. This protects the building's occupants as well as the surrounding community.
Energy Savings with Smart Controls
VAV hoods, setback, demand control and heat recovery cut fresh-air and fan energy. The savings continue for as long as the lab operates.
Limitations of Laboratory Exhaust Systems
Being clear about limitations helps you plan better. Each one below has a practical engineering answer.
High Energy Use from 100% Fresh Air
Conditioning outdoor air in a hot, humid climate is expensive. VAV hoods, night setback and heat recovery, planned from the start, bring this cost under control.
Complex Controls & Balancing
VAV and pressure-tracking systems need careful commissioning and trained operators. We provide clear control sequences, operator training and AMC support so the controls keep performing after handover.
Regular Testing & Certification Needed
Fume hoods, biosafety cabinets and monitors must be tested at least annually and after any change. Our AMC programme schedules this for you and keeps the records audit-ready.
Shaft & Roof Space for Ducts & Fans
Lab exhaust needs vertical shafts, plant space and roof area for fans and stacks. Involving us early lets your architect reserve the right space before layouts are frozen.
Where Laboratory Exhaust Systems Are Used
Any facility that handles hazardous chemicals or biological material needs a properly engineered lab exhaust system. These are the sectors we serve most often.
Pharmaceutical & Biotech Companies
QC, R&D, microbiology and pilot labs where GMP documentation, potent compounds and biosafety all meet. Reliability and validated performance are non-negotiable here.
Research Institutes
Research laboratory exhaust serving chemistry, life sciences and materials labs whose programmes change over time. Spare capacity and flexible manifolds make future changes easier.
Universities & Colleges
Teaching and research labs that need safe, durable and budget-conscious ventilation for many users with varying experience.
Hospitals & Diagnostic Centres
Pathology, histopathology, microbiology and molecular labs handling formaldehyde, xylene and clinical samples around the clock.
Chemical & Petrochemical Companies
Process development, QC and petroleum testing labs handling solvents, acids and flammable hydrocarbons that demand robust chemical laboratory exhaust.
Food & Water Testing Labs
Acid digestion, solvent extraction and instrument exhaust in accredited and in-house testing laboratories.
Forensic Laboratories
Evidence processing, fuming chambers and toxicology labs that need secure, well-documented containment.
Government & Defence Laboratories
Facilities that require high reliability laboratory exhaust with redundancy, backup power and rigorous documentation.
Top Laboratory Exhaust & Fume Hood Brands in India
Compress India works with the brand your consultant, client or corporate standard specifies and integrates it into a complete, tested exhaust system. All trademarks belong to their respective owners.
Kewaunee Scientific
A long-established name in laboratory furniture and fume hoods, with manufacturing operations in India. Its hoods are widely specified in pharmaceutical, academic and industrial labs, and we connect them to building exhaust, controls and monitoring.
Esco
Known for biosafety cabinets, fume hoods and laboratory equipment used widely across Asia. We connect Esco cabinets and hoods to building exhaust with the correct canopy or hard-duct interface.
Labconco
A US maker of fume hoods, biosafety cabinets and remote exhaust blowers. Where a Labconco exhaust fan or blower is specified with a Labconco hood, we install, duct and commission it as part of the overall system.
Thermo Fisher Scientific
A major supplier of biosafety cabinets and laboratory equipment. We integrate its cabinets into BSL-2 and BSL-3 exhaust and pressure-control designs.
Phoenix Controls (Lab Airflow Controls)
Known for venturi-type airflow control valves used in VAV and constant volume lab airflow control. When these valves are specified, we design the duct layout and tracking strategy around their requirements.
TSI (Fume Hood Monitors)
Known for fume hood monitors, room pressure monitors and airflow measurement instruments used in lab ventilation testing and certification.
Greenheck (High-Plume Exhaust Fans)
Offers laboratory exhaust fans, including high-plume designs, for safe stack discharge. We size plenums, bypass dampers and supports around the specified fan models.
Other Laboratory Equipment Brands
We also work with reputed Indian fume hood makers, PP and FRP blower manufacturers, filter and scrubber suppliers, and controls companies. Each is selected to suit your budget, chemistry and long-term service needs, so you get the best exhaust system for your lab rather than a one-brand compromise.
Laboratory Exhaust Installation Guide
A disciplined installation sequence protects quality, timelines and site safety. This is how Compress India delivers laboratory exhaust system installation, step by step.
Lab Layout & Services Coordination
We coordinate hood positions, duct routes, shafts, cable trays, gas lines, sprinklers and ceilings with your architect and MEP teams, resolving clashes on drawings before any fabrication begins.
Fume Hood & Biosafety Cabinet Installation
Hoods and cabinets are positioned away from doors, busy aisles and supply diffusers, then levelled, anchored and connected to exhaust, services and alarms according to manufacturer and project requirements.
PP, SS & Coated Duct Fabrication
PP fume hood ductwork is hot-air or extrusion welded; SS exhaust piping is welded or flanged with chemical-resistant gaskets; coated ducts are inspected for coating integrity. Joints are leak-tested, and slopes and drains are provided wherever condensate is expected.
Airflow Valve & Damper Installation
Airflow valves are installed with the straight-duct lengths and orientation their makers require, with access for calibration. NFPA 45 does not permit automatic fire dampers in chemical fume hood exhaust ducts, so fire separation is achieved through rated shafts instead.
Exhaust Fan & Stack Erection
Fans are mounted on vibration-isolated bases or roof curbs with flexible connections, drain points, weather protection and safe service access. Stacks are erected plumb, braced where needed and terminated at the designed height.
Controls, Monitors & Alarm Wiring
Monitors, valve controllers, pressure sensors and purge switches are wired, addressed and integrated with the BMS, with clear labelling for future maintenance teams.
Make-Up Air System Integration
Make-up air units, supply valves and terminal reheat are connected and sequenced with the exhaust so pressure relationships hold during start-up, normal operation, setback and power restoration.
Testing, Commissioning & Certification
A laboratory exhaust system is not finished until it is proven. Our laboratory exhaust commissioning process verifies performance and documents it for your records and auditors.
Fume Hood Face Velocity Testing
Face velocity is measured across a grid at the design sash height with calibrated thermal anemometers, averaged and compared against design targets. Readings at several sash positions confirm VAV response and monitor calibration.
ASHRAE 110 Tracer Gas Containment Test
A tracer gas is released inside the hood while a detector in a mannequin's breathing zone measures any escape. Static, sash-movement and perimeter tests give a numerical containment result, the most rigorous proof of hood performance. We perform or coordinate as-installed and as-used tests as your specification requires.
Smoke Visualisation Tests
Small- and large-volume smoke tests make airflow visible, revealing reverse flow, dead zones and leakage at the hood face, around the sash and at room doors.
Biosafety Cabinet Certification
Class II cabinets are field-certified to NSF/ANSI 49 by qualified certifiers, covering inflow and downflow velocity, HEPA filter integrity, smoke patterns and alarms. We coordinate certification and verify the canopy or hard-duct exhaust performance each cabinet depends on.
Room Pressure & Air Change Verification
Supply and exhaust volumes are measured, air change rates calculated, and differential pressures recorded with doors closed and open to confirm the pressure cascade.
Alarm & Emergency Mode Testing
Low-flow alarms, room pressure alarms, fan failure changeover, purge mode and power-restoration sequences are deliberately triggered and observed, never assumed.
Commissioning & Certification Reports
You receive a complete report with test data, instrument calibration details, balancing sheets, as-built drawings, control sequences and recommendations, ready for audits and annual recertification.
Laboratory Exhaust Service, Maintenance & AMC
Lab exhaust performance drifts over time as belts wear, filters load and controls lose calibration. A planned laboratory exhaust maintenance programme catches problems before they become failures or audit findings.
Annual Fume Hood Recertification
We retest face velocity, sash function, monitor calibration and smoke patterns at least once a year, and after relocations or system changes, labelling each hood with its test status and date.
Exhaust Fan, Motor & Belt Checks
Fan wheels, bearings, belts, vibration, motor current and drains are inspected on a set schedule. Even a corrosion resistant laboratory exhaust fan needs regular attention, especially in salty, humid coastal air.
Filter & Carbon Replacement
HEPA and carbon filters in BSCs, ductless hoods and exhaust units are monitored for pressure drop or saturation and replaced using documented, safe change-out procedures.
Duct Corrosion & Leak Inspection
Ducts, joints, hangers and roof penetrations are checked for cracking, corrosion, condensate and leaks, with particular attention to PP welds exposed to sunlight and SS joints near acid sources.
Airflow Valve & Monitor Calibration
Airflow valves, sash sensors, pressure sensors and monitors are verified against reference instruments and recalibrated, so the values your staff see remain trustworthy.
Scrubber Maintenance
Scrubber pumps, spray nozzles, packing, mist eliminators, pH dosing and blowdown are inspected and serviced to keep acid removal efficient and discharge within limits.
Common Laboratory Exhaust Problems & Solutions
Most lab exhaust complaints trace back to a handful of root causes. Here is how our engineers diagnose and fix them.
Low Fume Hood Face Velocity
Typical causes include a worn fan belt or dirty wheel, blocked baffles, closed or mis-set dampers, duct leaks, and hoods added beyond the fan's capacity. We measure, trace the system, restore balance and resize the fan where needed.
Frequent Fume Hood Alarms
Nuisance alarms usually point to uncalibrated monitors, sashes raised above the design opening, unstable duct static pressure or cross-drafts. Recalibration, sash stops and better pressure control usually resolve them.
Odours in Labs or Corridors
Odours suggest positive pressure, leaking ducts inside the building, poor hood practice or exhaust being drawn back in. A smoke and pressure survey locates the source quickly.
Lab Under Positive Pressure
When supply exceeds exhaust – through failed tracking, a stuck valve or a fan fault – lab air is pushed outward. We restore the airflow offset and add room pressure monitoring so it cannot go unnoticed again.
Doors Hard to Open or Whistling
An excessive offset in a tightly sealed room creates too much negative pressure. Resetting offsets, adding transfer paths where appropriate and rebalancing supply fixes the problem without losing containment.
Duct & Fan Corrosion
The wrong materials for the chemistry, condensate pooling or acid-laden air quickly destroy galvanised ducts and uncoated fans. Replacement with PP, SS, FRP or coated components and proper drainage provides a lasting fix.
Exhaust Re-Entering Fresh Air Intakes
Short stacks, low discharge velocity, rain caps or nearby intakes cause re-entrainment. High-plume fans, taller stacks or relocated intakes correct it.
Excessive Noise
High duct velocities, unbalanced fans, rigid connections and missing attenuators cause noise. Laboratory exhaust noise control combines correct velocities, vibration isolation, silencers and fans selected at efficient operating points.
High Energy Bills
CAV hoods running 24×7, sashes left open and no night setback waste large volumes of conditioned air. A VAV, setback and heat recovery upgrade often delivers significant savings.
Laboratory Exhaust Retrofit & Upgrades
Your existing lab can become safer and cheaper to run without a full rebuild. Our retrofit and exhaust system replacement services target the biggest gains first and are phased to keep your lab working.
Converting CAV to VAV Fume Hoods
Adding sash sensors, airflow valves and controllers converts many existing hoods to VAV, cutting exhaust and make-up air demand while holding face velocity steady.
Installing High-Plume Exhaust Fans
Replacing ageing roof fans with a laboratory high plume exhaust fan improves dispersion, adds redundancy and often removes the need for tall stacks.
Replacing Corroded Ducts with PP / SS
Corroded or leaking galvanised ducts are replaced with PP or SS sections, planned in phases and shutdown windows so critical work continues.
Adding Heat Recovery
Run-around coils or heat pipes can be added to existing exhaust and make-up air streams to reduce cooling load in high fresh-air facilities.
Adding Fume Hood & Room Pressure Monitors
Retrofitting monitors and alarms is one of the quickest and most affordable safety upgrades for any older laboratory.
Laboratory Exhaust System Cost in India
Laboratory exhaust system price in India depends mainly on the number and type of fume hoods, duct material and length, fan type, level of control and testing scope. The ranges below are indicative, exclusive of GST and based on current Indian market pricing; your project price is confirmed after a site survey.
| Item | Indicative range (₹, ex-GST) | What drives the price |
|---|---|---|
| Ducted fume hood, Indian make | ₹60,000 – ₹6,00,000+ | Size, body and liner material, sash type, services |
| Imported or high-performance ducted fume hood | ₹5,00,000 – ₹35,00,000 | Brand, low-flow design, VAV readiness |
| PP exhaust duct, round | ₹1,500 – ₹4,500 per metre | Diameter, wall thickness, fittings, supports |
| PP / FRP centrifugal exhaust blower | ₹20,000 – ₹1,35,000 | Airflow, static pressure, drive, motor |
| High-plume fans, VAV valves, monitors, BMS | Quoted per project | Number of hoods, redundancy, control scope |
Cost per Fume Hood
Indian-made ducted fume hoods typically range from about ₹60,000 for a basic bench unit to ₹6 lakh or more for larger, customised hoods, while imported high-performance hoods can cost several times that. Installed cost per hood rises once ducting, a share of the fan, controls and testing are added, which is why we always quote the complete system rather than the hood alone.
Ductwork, Fans & Stack Cost
PP duct typically costs ₹1,500–₹4,500 per running metre depending on size and thickness, with fittings, supports and roof penetrations extra. Stainless steel exhaust tubing and ductwork cost more but are essential for heat, solvent and perchloric duty. FRP laboratory exhaust blowers generally fall between ₹20,000 and ₹1.35 lakh each; high-plume fans, stacks and N+1 arrangements are quoted per project.
Airflow Controls & Monitoring Cost
A basic face velocity monitor on each hood is an economical safety add-on. Room pressure monitors, VAV valve packages, tracking controls and BMS integration add progressively more cost, but VAV and setback controls also bring the largest operating savings, so we show you the expected payback before you decide.
Factors Affecting Total Project Cost
- Number, size and type of fume hoods and biosafety cabinets
- Chemical profile and required duct material (PP, SS or coated)
- Duct length, shaft routes and building height
- Fan type – standard centrifugal, mixed flow or high-plume – and N+1 redundancy
- CAV or VAV control, monitoring and BMS integration
- Scrubbers, carbon or HEPA treatment before discharge
- Make-up air capacity and heat recovery
- Testing, certification and AMC scope
- Site conditions such as occupied-facility working, night shifts and access
Share your hood list and drawings for an itemised quotation with no hidden extras.
Laboratory Exhaust Design & Installation in Mumbai, Navi Mumbai & Thane
Compress India delivers laboratory exhaust design, installation, testing and AMC across Mumbai, Navi Mumbai and Thane for pharmaceutical, biotech, chemical, hospital, academic and testing laboratories.
We serve research and QC labs in Andheri, Powai, Vikhroli and Goregaon; industrial and pharmaceutical facilities along the Thane–Belapur belt, including Mahape, Rabale, TTC and Taloja; and labs across Thane, Bhiwandi and Ambernath. Our team surveys your site, designs the system and supports it long after handover.
The region's coastal climate brings its own challenges: heavy humidity loads on 100% fresh make-up air, salt-laden air that attacks roof fans and stacks, and monsoon rain on exposed equipment. We design for these conditions with corrosion-resistant fans, stacks with drains instead of rain caps, dehumidifying make-up air and maintenance plans timed around the monsoon.
Unlike general exhaust companies that treat lab ventilation as an ordinary fan job, we approach it as a safety-critical system. Book a site visit in Mumbai, Navi Mumbai or Thane today.
Why Choose Compress India for Laboratory Exhaust Systems?
Choosing a laboratory ventilation contractor is a safety decision as much as a commercial one. Whether you are comparing a laboratory exhaust system manufacturer, a fabricator or an HVAC contractor, here is what you get with Compress India.
Laboratory Ventilation Design Expertise
Our engineers design lab exhaust from first principles – risk assessment, CFM calculation, fan sizing and dispersion – rather than rules of thumb, and align every design with recognised standards.
Risk-Based Airflow & Pressure Design
Air changes, face velocities and pressure offsets are set by your actual hazards and processes, so you neither over-ventilate safe areas nor under-protect risky ones.
PP, SS & Coated Duct Fabrication
We fabricate and install laboratory chemical resistant ductwork matched to your chemistry, with quality welding, proper supports and leak testing.
Fume Hood, Fan & Controls Integration
One team takes responsibility for hoods, BSC connections, fans, valves, monitors and make-up air, eliminating the gaps that appear between separate vendors.
Testing & Certification Support
Face velocity, smoke, containment, pressure and alarm testing with documented reports, plus coordination of biosafety cabinet certification.
Energy-Efficient Lab Ventilation
VAV, setback, demand control, heat recovery and variable-volume fans, each evaluated for real payback against your operating hours.
AMC & Annual Recertification
Planned maintenance, annual hood recertification, calibration and responsive breakdown support keep your lab safe and audit-ready year after year.
Get a Laboratory Exhaust Solution from Compress India
Whether you are building a new lab, expanding an existing one or fixing a system that keeps failing tests, we will help you get it right first time.
Connect with Our HVAC Team
Share a few details and we will come back with practical next steps and a quotation:
- Lab type and floor area
- Number and type of fume hoods and biosafety cabinets
- Main chemicals or biological agents handled
- Drawings or photos of any existing installation
- Target completion date
Call: [Phone number] · Email: [Email address] · Office: [Address]
Request a site survey and quotation for your laboratory exhaust system today.
Related Chemical Exhaust, Fume Extraction & Cleanroom Solutions
Laboratory exhaust is often one part of a wider project. Explore our related services: Chemical Exhaust Systems – for process areas, chemical stores and plant rooms, Fume Extraction Systems – local exhaust for workshops, instrument rooms and production areas, Cleanroom Solutions – HVAC, pressure cascades and validation for controlled environments

Toilet Exhaust Ventilation Systems
Learn More
Kitchen Exhaust Systems
Learn More
DG Room Ventilation Systems
Learn More
Basement Exhaust Systems
Learn More
Electrical Room Ventilation
Learn MoreFrequently Asked Questions
Q1. What is a laboratory exhaust system?
A laboratory exhaust system captures hazardous fumes, vapours and aerosols at fume hoods, biosafety cabinets and other local exhaust points, carries them through chemical-resistant ducts and discharges them safely above the roof through laboratory exhaust fans. It also keeps the lab at negative pressure relative to surrounding areas.
Q2. How does a laboratory exhaust system work?
Fume hoods and local exhaust draw contaminated air in at controlled velocities, general exhaust maintains the room's air changes, ducts carry the air to roof fans, and the fans discharge it through high stacks. Supply air is controlled slightly below exhaust so air always flows into the lab, not out of it.
Q3. What is the recommended face velocity for a fume hood?
Conventional fume hoods are commonly set at about 0.4–0.5 m/s (80–100 fpm) at the design sash opening. High-performance hoods may operate at lower velocities when containment is verified by ASHRAE 110 or EN 14175 testing. Face velocity alone does not prove containment, so smoke and tracer gas tests are recommended for critical hoods.
Q4. What is the difference between ducted and ductless fume hoods?
Ducted fume hoods exhaust fumes outdoors and handle a broad range of chemicals and volumes. Ductless hoods filter air through carbon or HEPA media and return it to the room; they suit small, well-defined, low-volume tasks and need careful filter monitoring and replacement.
Q5. What is the difference between a fume hood and a biosafety cabinet?
A fume hood protects users from chemical vapours by exhausting them outdoors. A biosafety cabinet uses HEPA filtration to protect users, samples and the environment from biological agents. Biosafety cabinets are not designed for significant volumes of volatile chemicals.
Q6. How many air changes per hour does a laboratory need?
There is no single number. Many chemical labs are designed for roughly 6–12 ACH when occupied, with a lower rate when unoccupied if the risk assessment allows. DBT containment guidelines call for at least 12–15 ACH in BSL-3 laboratories. The final rate is set by risk, fume hood exhaust and heat load.
Q7. Why should laboratories be kept at negative pressure?
Negative pressure makes air flow from corridors into the lab, so fumes, odours and aerosols released in the lab cannot drift into offices, corridors or public areas. It is an important secondary barrier behind fume hoods and biosafety cabinets.
Q8. What is a VAV fume hood and how does it save energy?
A VAV fume hood adjusts its exhaust volume to hold a constant face velocity as the sash moves. Lowering the sash reduces exhaust, and with it the conditioned fresh air the building must supply, which can significantly cut cooling and fan energy in multi-hood labs.
Q9. What is a high-plume laboratory exhaust fan?
A high-plume laboratory exhaust fan mixes lab exhaust with outside air and discharges it at high velocity so the plume rises well above the roof. This dilutes contaminants and reduces the risk of exhaust re-entering fresh air intakes, often without the need for very tall stacks.
Q10. How often should fume hoods be tested and certified?
Fume hoods should be tested at least once a year, and after installation, relocation, repairs or system changes. Biosafety cabinets are certified at installation, at least annually, and after relocation or filter changes, in line with NSF/ANSI 49 practice. Airflow monitors should be calibrated at each test.
Q11. What is the cost of a laboratory exhaust system in India?
Cost depends on scope. Indian-made ducted fume hoods typically range from about ₹60,000 to ₹6 lakh or more, PP ducting from about ₹1,500 to ₹4,500 per metre, and PP/FRP exhaust blowers from about ₹20,000 to ₹1.35 lakh, excluding GST. Controls, high-plume fans and testing are quoted per project. Contact Compress India for an itemised quotation based on your layout.
Q12. Does Compress India design and install laboratory exhaust systems in Mumbai?
Yes. Compress India designs, supplies, installs, tests and maintains laboratory exhaust systems across Mumbai, Navi Mumbai and Thane, and can discuss projects in other parts of India on request. Contact our HVAC team to book a site survey.