Cassette Air Conditioning Units
(Supply, Installation, Service, Repair & AMC for Ceiling Cassette AC Systems)
Supply, Installation, Service, Repair & AMC for Ceiling Cassette AC Systems
Need even, powerful cooling for an office, showroom, restaurant or clinic without cluttering your walls? Cassette Air Conditioning Units sit neatly inside the false ceiling and spread cool air in every direction, making them the preferred choice for commercial and open-plan spaces.
Compress India supplies, installs, services and maintains ceiling cassette ACs from leading brands. Our HVAC team plans the right tonnage, unit positions, false ceiling coordination and drain routing, so your space looks clean and stays comfortable. Share your layout today and request a detailed quotation.

Compress India is your single point of contact for every stage of your cassette AC system.
- Supply: Genuine 1-way, 2-way, 4-way and 360° round flow cassette ACs, inverter and non-inverter, from 1.5 ton to 4 ton and above.
- Installation: Professional cassette AC installation with correct suspension, levelling, copper piping, drain pump lift, vacuuming and testing.
- Service: Filter, coil, fan, drain pump and drain tray cleaning to keep airflow and cooling strong.
- Repair: Fixes for water dripping, drain pump failure, gas leaks, error codes, PCB and airflow problems.
- AMC: Comprehensive and non-comprehensive AMC plans for offices, retail chains, hotels and commercial buildings.
With one accountable team, your cassette air conditioning units are planned right, installed right and maintained right.
What Is a Cassette Air Conditioner?
A cassette air conditioner is a ceiling mounted split AC whose indoor unit is fitted inside the false ceiling, with only a flat decorative panel visible from below. It connects to an outdoor condensing unit through refrigerant piping, just like a regular split AC.
Also known as a ceiling cassette AC, cassette type air conditioner or in ceiling split AC, it throws air in up to four directions or a full 360°. This gives uniform air distribution across large rooms, which is why cassette air conditioning units are standard in offices, showrooms, restaurants, banks and clinics.
How a Cassette AC Works
A cassette AC system works on the same refrigeration cycle as other split ACs. What sets it apart is where the indoor unit sits and how it distributes air.
Ceiling-Mounted Indoor Unit
The cassette AC indoor unit hangs above the false ceiling. It draws warm room air through a central return grille, cools and dehumidifies it over the evaporator coil, and pushes it back into the room.
Outdoor Condensing Unit
The cassette AC outdoor unit contains the compressor, condenser coil and fan. It releases the heat absorbed indoors to the outside air and is placed on a terrace, ledge, podium or dedicated outdoor area.
Refrigerant Piping Between Units
Insulated copper pipes run through the ceiling void to connect both units. Correct pipe size, length and insulation protect cooling capacity and prevent condensation drips on the false ceiling.
Multi-Directional Air Throw Through Louvers
Motorised louvers on the panel direct cool air in one, two, four or 360° directions. This spreads air evenly, avoids cold spots and prevents strong draughts on people below.
Built-In Drain Pump for Condensate Removal
Because the unit sits inside the ceiling, gravity drainage is not always possible. A cassette AC with built in drain pump lifts condensate water up to about 500–850 mm, depending on the model, before it flows to the drain line.
Main Components of a Cassette AC
Cassette Indoor Body
The indoor cassette unit body holds the coil, fan, drain tray and drain pump. It is suspended from the slab with threaded rods and sits within the ceiling void.
Decorative Panel & Grille
The visible panel covers the ceiling opening and includes the return air grille and supply louvers. Its clean square or round design blends with modern interiors.
Turbo Fan & Evaporator Coil
A centrifugal turbo fan pulls air up through the filter and pushes it across a wrap-around evaporator coil. This design delivers strong airflow with low noise.
Drain Pump & Drain Tray
The drain tray collects condensate from the coil, and the drain pump lifts it to the drain pipe. A float switch stops the unit if water rises too high, protecting your ceiling.
Air Filters
Washable filters behind the return grille trap dust and particles. Many models accept optional purification filters for better indoor air quality.
Outdoor Unit (Compressor & Condenser)
The outdoor unit houses the compressor, condenser coil and fan. Inverter compressors adjust speed to demand, cutting power use in offices with varying occupancy.
Wired / Wireless Remote Controls
Cassette ACs work with wireless remotes or wall-mounted wired controllers. Wired controllers are preferred in commercial spaces for central scheduling, lock functions and BMS integration.
Types of Cassette AC Units
Cassette air conditioning units come in several formats. The right type depends on room shape, ceiling size and how the air needs to flow.
4-Way Cassette AC
The four way cassette AC is the most common commercial cassette AC. It blows air in four directions from the centre of the room, making it ideal for offices, showrooms and conference rooms. A 4-way cassette AC for commercial space typically ranges from 2 to 4 ton.
360° Round Flow Cassette AC
A 360 degree cassette AC, also called a round cassette AC, spreads air in a full circle. It eliminates corner hot spots and draughts, delivering the most even cooling in square or irregular rooms.
1-Way & 2-Way Cassette AC
A one way cassette air conditioner, also called a single flow or single way cassette AC, throws air in one direction and fits along walls, corridors and narrow spaces. A 2 way cassette AC blows air to two opposite sides and suits long, rectangular rooms such as bank halls and classrooms.
Compact (600 x 600) Cassette AC
A compact cassette air conditioner fits a standard 600 x 600 mm ceiling grid, replacing one ceiling tile. These mini cassette air conditioners, usually 1 to 2 ton, suit cabins, small offices, clinics and even a ceiling cassette air conditioner for home use.
Inverter vs Non-Inverter Cassette AC
| Parameter | Inverter Cassette AC | Non-Inverter Cassette AC |
|---|---|---|
| Compressor | Variable speed | Fixed speed, on/off |
| Power consumption | Lower, especially at part load | Higher |
| Temperature control | Stable | Fluctuates |
| Noise | Lower | Higher at start-up |
| Upfront cost | Higher | Lower |
| Best for | Long operating hours, varying occupancy | Short, fixed usage |
An inverter cassette AC for office use usually recovers its extra cost quickly, as offices run the AC for 8–12 hours a day.
VRF / VRV Cassette Indoor Units
In larger buildings, a VRF cassette indoor unit or VRV cassette AC connects to a central VRF outdoor system. This lets many rooms and floors share one outdoor plant with individual control, making the cassette AC for VRF system use common in corporate offices, hotels and hospitals.
Chilled Water Cassette FCUs
In buildings with a central chiller plant, chilled water cassette fan coil units (FCUs) circulate chilled water instead of refrigerant. They are used in malls, IT parks, hotels and hospitals with central HVAC.
Cassette AC Capacity Guide – How Many Tons Do You Need?
Correct cassette AC tonnage ensures fast, even cooling without wasting power. Too small, and the room never cools; too large, and humidity control suffers.
Common Cassette AC Capacities
- 1 – 1.5 Ton: Compact cassettes for cabins, clinics and small offices.
- 2 Ton Cassette AC: Conference rooms, small showrooms, cafés.
- 2.5 – 3 Ton Cassette AC: Open offices, retail stores, restaurants.
- 4 Ton and above: Large halls, banquet areas, gyms; often combined as multiple units.
Area vs Tonnage Chart
| Area (sq ft) | Typical Space | Recommended Cassette AC Capacity |
|---|---|---|
| 120–180 | Cabin, consultation room | 1–1.5 ton compact cassette |
| 180–250 | Conference room, small shop | 2 ton |
| 250–350 | Office bay, showroom | 2.5–3 ton |
| 350–450 | Restaurant, open office | 3–4 ton |
| 450+ | Hall, banquet, gym | Multiple cassette units |
This chart assumes a 10 ft ceiling and normal commercial load. We confirm capacity after a detailed heat load calculation.
Factors Affecting Cooling Load (Occupancy, Glass Area, Equipment)
- Occupancy: Restaurants, classrooms and gyms need more capacity per sq ft than offices.
- Glass area: Large glass facades in showrooms add significant solar heat.
- Equipment: Computers, kitchen equipment, lighting and display screens add heat.
- Ceiling height: High ceilings need higher capacity and correct air throw.
- Floor level and exposure: Top floors and west-facing spaces need extra margin.
Send us your floor plan, and our engineers will calculate the exact cassette AC cooling capacity and positions for your space.
Energy Efficiency of Cassette ACs
Commercial spaces run their ACs for long hours, so an energy efficient cassette AC has a direct impact on monthly operating costs.
Inverter Technology & Power Savings
An inverter cassette air conditioner runs the compressor at the speed the room actually needs. When occupancy drops at lunch or after hours, power use drops too. Compared with fixed-speed units, inverter models can cut energy consumption by 30–50% in typical office use.
Energy Efficiency Ratings
Cassette ACs are compared using EER, ISEER or seasonal efficiency figures, and many inverter models carry BEE star ratings. A higher rating means more cooling for every unit of electricity. Our team helps you compare efficiency figures across brands for your usage pattern.
Refrigerants Used (R32 / R410A)
Most modern cassette ACs use R32 or R410A. An R32 cassette AC offers high efficiency, a smaller refrigerant charge and lower global warming potential. R410A remains common in larger capacities and VRF cassette units.
False Ceiling Requirements for Cassette ACs
A cassette AC for false ceiling installation needs careful coordination with your interior contractor. Planning these details early avoids costly rework.
Minimum Ceiling Void Depth
Most cassette bodies need a ceiling void of about 250–350 mm between the slab and false ceiling, depending on the model. Compact and slim ceiling cassette air conditioners need less depth.
Ceiling Height & Air Throw
Standard cassette ACs work best at finished ceiling heights of about 2.7 to 3.5 metres. Higher ceilings need units with high-ceiling settings or stronger air throw to reach the occupied zone.
Panel Cut-Out Size
The false ceiling opening must match the unit body, typically about 840–890 mm square for standard 4-way units and about 570–600 mm for compact 600 x 600 models. Exact sizes vary by brand and are shared with your interior team.
Suspension & Support Rods
The indoor unit is hung from the concrete slab using anchor fasteners and threaded rods, never from the false ceiling framework. This keeps it level, secure and vibration-free.
Service Access Panels
Removable access panels near refrigerant joints, the drain connection and the control box make future servicing easy without breaking the ceiling.
Key Features to Look for in a Cassette AC
The best cassette air conditioner for your space combines strong performance with features that suit commercial use.
4-Way / 360° Uniform Airflow
A ceiling mounted cassette AC with 4-way airflow or 360° round flow delivers uniform air distribution, eliminating hot and cold spots in open areas.
Individual Louver Control
Individual louver control lets you adjust or close each outlet separately. This is useful when a unit sits near a wall, a glass facade or a workstation that should not get direct airflow.
Built-In Drain Pump
A built-in drain pump lifts condensate so drain lines can be routed neatly above the ceiling, even when the nearest drain point is higher than the unit.
Fresh Air Intake Option
Many cassettes offer a cassette AC fresh air intake knockout to connect treated outdoor air. This improves indoor air quality in meeting rooms, classrooms and clinics.
Air Purification Filters
Optional PM 2.5, anti-bacterial and ioniser filters help reduce dust, allergens and airborne germs in busy commercial spaces.
Occupancy & Floor Sensing
Advanced models use infrared sensors to detect people and floor temperature. They redirect airflow and reduce output when rooms are empty, saving energy automatically.
Wi-Fi & BMS Connectivity
A smart cassette AC with Wi-Fi control lets managers monitor and schedule units remotely. Cassette AC BMS integration links units to building management systems for central control across floors or sites.
Low Noise Operation
A low noise cassette AC runs quietly enough for boardrooms, banks, clinics and hotel lobbies, keeping conversations and presentations undisturbed.
Benefits of Cassette ACs
Cassette air conditioning units combine performance and design in a way few other systems can.
Uniform Cooling for Large Spaces
Central ceiling placement and multi-directional airflow cool the entire room evenly, not just the area in front of the unit.
Saves Wall & Floor Space
With the unit hidden in the ceiling, walls stay free for displays, shelving, artwork and windows, and floors stay clear of tower units.
Sleek, Concealed Ceiling Design
Only a slim panel is visible, blending with light fixtures and ceiling grids for a premium, professional look.
Higher Capacity Than Split ACs
Cassette units are available from about 1 ton up to 4 ton or more, handling larger spaces that a single hi wall split AC cannot cool effectively.
Quiet Operation
The compressor runs outdoors and the turbo fan is designed for low noise, keeping offices, banks and clinics calm.
Ideal for Open-Plan Areas
Multiple cassettes can be spaced across an open floor to deliver consistent comfort in every zone.
Limitations of Cassette ACs
Requires a False Ceiling
Standard cassettes need a false ceiling with enough void depth. A cassette AC without false ceiling is possible only with special exposed frames or boxing, which affects the look.
Higher Installation Cost
Ceiling work, suspension, drain routing and coordination with interiors make cassette AC installation costlier than a wall mounted split AC.
Drain Pump Maintenance
The drain pump and tray must be cleaned regularly. A neglected pump can cause water dripping on the ceiling.
Not Suitable for Small Rooms
In very small rooms, a standard cassette may be oversized and costly. A hi wall split AC or compact cassette is usually more practical.
Cassette AC vs Split AC
| Parameter | Cassette AC | Hi Wall Split AC |
|---|---|---|
| Mounting | Inside the false ceiling | High on the wall |
| Airflow | 1, 2, 4-way or 360° | One direction |
| Capacity | About 1 to 4 ton+ | About 0.75 to 2.5 ton |
| Best for | Offices, showrooms, restaurants | Bedrooms, cabins, small rooms |
| Look | Concealed, flush with ceiling | Visible on the wall |
| Installation cost | Higher | Lower |
In the cassette AC vs hi wall AC choice, cassettes win for larger, open, commercial areas, while split ACs are more economical for individual rooms.
Cassette AC vs Ducted AC
| Parameter | Cassette AC | Ducted AC |
|---|---|---|
| Air distribution | Directly from ceiling panel | Through ducts and diffusers |
| Visibility | Panel visible | Only grilles visible |
| Ceiling depth needed | Moderate | Higher, for ducts |
| Coverage | One zone per unit | Several rooms per unit |
| Installation | Faster, simpler | More complex, higher cost |
For open offices and showrooms, cassette ACs are quicker to install and easier to zone. Ducted ACs suit spaces that need a fully concealed look or cooling across several connected rooms.
Cassette AC vs Tower AC
| Parameter | Cassette AC | Tower AC |
|---|---|---|
| Placement | In the ceiling | On the floor |
| Floor space used | None | Occupies floor area |
| Air distribution | Even, multi-directional | Strong forward throw |
| False ceiling | Required | Not required |
| Best for | Offices, showrooms, restaurants | Halls, temporary setups, spaces without false ceiling |
Choose a cassette AC when floor space and aesthetics matter; choose a tower AC when there is no false ceiling or you need a quick, portable-style solution.
Where Cassette ACs Are Used
Cassette air conditioning units are the go-to ceiling AC unit for commercial buildings and premium residential spaces.
Offices & Conference Rooms
A ceiling cassette air conditioner for office use cools workstations evenly and keeps walls free. A cassette AC for conference room use delivers quiet, draught-free comfort during meetings.
Retail Showrooms & Shops
A cassette AC for retail store or showroom use keeps customers comfortable while leaving walls open for displays and branding.
Restaurants & Cafés
A cassette AC for restaurant spaces handles high occupancy and kitchen heat while blending into the interior design.
Banks & Financial Offices
2-way and 4-way cassettes cool long banking halls and cabins evenly, with quiet operation for customer interactions.
Clinics & Hospitals
Cassettes with purification filters and fresh air intake suit OPDs, waiting areas, consultation rooms and diagnostic centres.
Hotel Lobbies & Banquet Halls
A cassette AC for hotel lobbies, restaurants and banquet halls provides uniform comfort for large gatherings with a clean ceiling finish.
Schools & Coaching Classes
Classrooms stay cool and quiet for learning, and 2-way cassettes suit long rectangular rooms well.
Gyms & Fitness Centres
High-capacity 4-way cassettes handle heavy occupancy and body heat while keeping floor space free for equipment.
Premium homes also use ceiling mounted air conditioner residential installations in living rooms and home theatres where a concealed look is preferred.
Top Cassette AC Brands in India
Compress India supplies and services cassette ACs from leading brands, helping you compare features, efficiency and pricing in one place.
Daikin
Daikin offers a wide range of round flow and 4-way cassettes, along with VRV cassette indoor units. Contact us for current daikin cassette air conditioner price details and daikin ceiling mounted air conditioner options.
Blue Star
Blue Star is a trusted name in commercial cooling, offering reliable cassette ACs for offices, retail and hospitality projects.
Voltas
Voltas cassette ACs offer dependable performance and value across popular commercial capacities.
LG
LG cassette ACs feature inverter compressors, 4-way and round flow panels and smart control options for modern commercial spaces.
Samsung
A samsung cassette air conditioner or samsung ceiling cassette air conditioner features wind-free cooling that spreads air gently through micro-holes, reducing direct draughts.
Mitsubishi Electric
Mitsubishi electric cassette ac models are known for quiet operation and premium build. Mitsubishi ceiling cassette air conditioner and mitsubishi electric ceiling air conditioner options suit executive offices and high-end commercial interiors.
Carrier
Carrier cassette ACs offer robust cooling for commercial buildings, restaurants and retail spaces.
Hitachi
Hitachi cassettes are known for strong compressors and dependable performance in high ambient temperatures.
O General
O General cassette ACs are known for durable build and efficient cooling in commercial and residential applications.
Cassette AC Installation Guide
Cassette AC installation involves ceiling, drainage, piping and electrical work. Done correctly, it prevents leaks, noise and poor cooling for years. Here is how our team installs every unit.
Choosing the Right Ceiling Location
Position the unit centrally in its cooling zone, away from light fittings, beams and sprinklers. Keep enough clearance from walls so all outlets can throw air freely, and avoid placing it directly above workstations or seating.
Indoor Unit Suspension & Levelling
The unit is hung from the slab using anchor fasteners and threaded rods, then levelled precisely. Correct levelling is essential for proper drainage and quiet running.
Copper Piping Length & Insulation
Copper pipes are sized to the manufacturer's specifications and kept within the maximum length and height limits. Both lines are fully insulated to prevent condensation dripping onto the false ceiling.
Drain Piping & Drain Pump Lift
Drain pipes are routed with a steady downward slope after the pump's lift point and insulated to avoid sweating. We test the drain pump by pouring water into the tray before closing the ceiling.
Outdoor Unit Placement
The outdoor unit is placed in a well-ventilated area with enough clearance for airflow and service, on a sturdy stand with anti-vibration pads.
Electrical Wiring & Protection
Each unit gets a dedicated power supply with the correct MCB or isolator, properly rated cables and earthing. Voltage protection is added where supply fluctuates.
Vacuuming, Gas Charging & Testing
The system is pressure tested for leaks, vacuumed to remove air and moisture, and charged with additional refrigerant for long pipe runs. We then check pressures, temperatures, airflow and controls before handover.
Ask us for a clear, itemised cassette AC installation quote before work begins.
Cassette AC Service, Maintenance & AMC
Regular cassette AC maintenance protects cooling, efficiency and your ceiling from water damage.
Filter Cleaning Frequency
Clean filters every 2–4 weeks in busy commercial spaces, and monthly in lighter-use areas. Dirty filters restrict airflow and increase power consumption.
Coil & Fan Cleaning
The evaporator coil and turbo fan are cleaned with coil cleaner 2–4 times a year to remove dust and biological growth that reduce cooling.
Drain Pump & Drain Tray Cleaning
The drain tray and pump are flushed and cleaned during each service to prevent sludge, blockages and ceiling leaks.
Gas Pressure & Leak Checks
Our technicians check refrigerant pressures and inspect joints for leaks. Leaks are repaired before any gas charging.
Comprehensive vs Non-Comprehensive AMC
| Parameter | Comprehensive AMC | Non-Comprehensive AMC |
|---|---|---|
| Preventive services | Included | Included |
| Breakdown calls | Included | Included |
| Spare parts | Most parts included | Charged extra |
| Gas charging | Usually included | Charged extra |
| Best for | Offices, retail chains, older systems | New units under warranty |
Our cassette AC service plans are tailored for single sites, multi-location businesses and large commercial buildings.
Common Cassette AC Problems & Solutions
Water Dripping from the Ceiling
Causes: Blocked drain, faulty drain pump, poor drain slope, uninsulated pipes or an unlevelled unit. Solution: Clean the drain system, test the pump, correct the slope and insulate lines.
Drain Pump Failure
Causes: Sludge build-up, a stuck float switch or a burnt pump motor. Solution: Clean or replace the pump and float switch.
AC Not Cooling Properly
Causes: Dirty filters, clogged coils, low gas or undersized capacity. Solution: Service the unit, check refrigerant and review the heat load.
Uneven Airflow
Causes: Blocked or incorrectly set louvers, a dirty fan or poor unit placement. Solution: Clean the fan, reset louver angles and review positioning.
Noise or Vibration
Causes: Loose suspension rods, an unbalanced fan or worn outdoor unit mounts. Solution: Tighten and re-level the unit, balance or replace the fan and fit anti-vibration pads.
Bad Smell from the AC
Causes: Mould in the coil or stagnant water in the drain tray. Solution: Deep clean the coil, fan and tray, and keep up a regular service schedule.
Error Codes on Display
Causes: Drain pump alarms, sensor faults, communication errors or gas issues. Solution: Note the code and call our team for brand-specific diagnosis and repair.
Cassette AC Price in India
Cassette AC price in India depends on capacity, airflow type, brand, efficiency and site conditions. The figures below are indicative ranges for planning. Contact Compress India for an exact cassette air conditioner price for your project.
Cassette AC Price by Tonnage
| Capacity | Indicative Price Range (Unit Only) |
|---|---|
| 1.5 Ton Cassette AC | ₹55,000 – ₹85,000 |
| 2 Ton Cassette AC | ₹65,000 – ₹1,00,000 |
| 3 Ton Cassette AC | ₹85,000 – ₹1,40,000 |
| 4 Ton Cassette AC | ₹1,10,000 – ₹1,70,000 |
Prices vary with inverter technology, round flow or wind-free panels, smart controls and brand. VRF cassette indoor units are priced as part of the overall VRF project.
Installation Charges
Cassette AC installation cost depends on the site. Typical elements include:
- Indoor unit suspension, levelling and panel fixing
- Copper piping, insulation and cable runs
- Drain piping and drain pump testing
- Outdoor unit stand and anti-vibration pads
- Core cutting and ceiling coordination
- Additional refrigerant for long pipe runs
- Electrical point, MCB or isolator
We provide a transparent, itemised quote so you know the full cassette air conditioner cost upfront.
Factors Affecting Price
- Capacity and number of units
- 1-way, 2-way, 4-way or 360° panel type
- Inverter or non-inverter compressor
- Brand, efficiency and warranty
- Air purification, fresh air, sensor and Wi-Fi features
- Piping length, ceiling height and site access
- False ceiling and drain routing requirements
Cassette AC Supply, Installation & Service in Mumbai, Navi Mumbai & Thane
Compress India supplies, installs and services cassette air conditioning units across Mumbai, Navi Mumbai and Thane. Our teams work closely with architects, interior designers and site contractors to coordinate ceiling cut-outs, drains and outdoor unit locations, keeping projects on schedule.
From a single cassette AC for a clinic in Thane to a full office floor in BKC or a restaurant chain across Navi Mumbai, we deliver planned installations and dependable after-sales service. Our local presence means faster site visits, quicker repairs and responsive AMC support.
Why Choose Compress India for Cassette ACs?
Multi-Brand Supply
We offer cassette ACs from leading brands, so you get unbiased advice and competitive pricing in one place.
Correct Tonnage & Layout Planning
Our engineers calculate the heat load and plan unit positions for even cooling across your floor plan.
False Ceiling & Drain Coordination
We share cut-out sizes, void depths and drain routes with your interior team early, avoiding rework and delays.
Professional Installation
Trained technicians, proper suspension, quality copper piping, vacuuming and drain testing ensure long-lasting performance.
Repair & Gas Charging
Fast diagnosis of leaks, drain pump faults and error codes, with genuine spares and leak-first gas charging.
AMC & Preventive Maintenance
Flexible AMC plans keep your cassette ACs clean, efficient and leak-free throughout the year.
Commercial & Bulk Projects
We manage multi-unit supply and installation for offices, retail chains, hotels, hospitals, schools and builders, with dedicated project coordination and bulk pricing.
Get a Cassette AC Solution from Compress India
Planning a new office, showroom or restaurant, or upgrading an existing space? Share your floor plan and requirements, and we will recommend the right cassette air conditioning units with a detailed quotation.
Connect with Our HVAC Team
Call, WhatsApp or fill out our enquiry form with your area, ceiling height, location and preferred brand. Our HVAC experts will get back to you with advice, a site survey if required and a competitive quote. Request your free cassette AC quotation today.
Related Air Conditioning Solutions

Split / Hi Wall Air Conditioning Units
Learn More
Floor Standing Air Conditioning Units
Learn More
Ducted Air Conditioning Units
Learn More
Packaged Air Conditioning Units
Learn More-Photoroomsa.png&w=3840&q=75)
Packaged (Split Type) Air Conditioning Units
Learn MoreFrequently Asked Questions
Q1: What is a cassette air conditioner?
A cassette air conditioner is a ceiling mounted split AC whose indoor unit sits inside the false ceiling, with only a slim panel visible. It spreads air in one, two, four or 360° directions for even cooling.
Q2: How does a cassette AC work?
The indoor unit draws room air through a central grille, cools it over the evaporator coil and blows it out through louvers. Refrigerant carries the heat to the outdoor unit, and a built-in drain pump removes condensate.
Q3: What is the difference between a cassette AC and a split AC?
A cassette AC is mounted in the ceiling and distributes air in several directions, suiting larger commercial spaces. A hi wall split AC is mounted on the wall, blows air in one direction and suits individual rooms.
Q4: Is a cassette AC better than a ducted AC?
For open offices, showrooms and restaurants, cassette ACs are faster and more economical to install. Ducted ACs are better when you want a fully concealed system or need to cool several connected rooms from one unit.
Q5: How many tons of cassette AC do I need for my office?
As a general guide, allow about 2 ton for 180–250 sq ft and 3 ton for 250–350 sq ft, adjusted for occupancy, glass and equipment. Share your floor plan with Compress India for an accurate heat load calculation.
Q6: Does a cassette AC need a false ceiling?
Yes, standard cassette ACs are designed for a false ceiling with a void of about 250–350 mm. Where there is no false ceiling, we can suggest alternatives such as ceiling suspended, hi wall or tower units.
Q7: What is a 4-way cassette AC?
A 4-way cassette AC blows cool air in four directions from a central ceiling position. It delivers uniform cooling across square rooms such as offices, showrooms and conference rooms.
Q8: Why is water dripping from my cassette AC?
Common causes include a blocked drain, a faulty drain pump or float switch, poor drain slope, uninsulated pipes or an unlevelled unit. Switch off the AC and call a technician to prevent ceiling damage.
Q9: How often should a cassette AC be serviced?
Clean filters every 2–4 weeks and schedule a full service with coil, fan and drain pump cleaning 3–4 times a year for commercial use. An AMC ensures this happens on time.
Q10: Are inverter cassette ACs more energy efficient?
Yes. Inverter cassette ACs adjust compressor speed to the actual load, typically saving 30–50% electricity in offices and shops with changing occupancy.
Q11: What is the price of a cassette AC in India?
Cassette AC prices typically range from about ₹55,000 for a 1.5 ton unit to ₹1,70,000 or more for a 4 ton unit, depending on brand and features. Installation is extra. Contact Compress India for current prices.
Q12: Does Compress India provide cassette AC installation and service in Mumbai?
Yes. Compress India provides cassette AC supply, installation, repair, gas charging and AMC across Mumbai, Navi Mumbai and Thane for offices, retail, hospitality, healthcare and residential projects. Get in touch today for a free quotation.